Notifications
You must be signed in to change notification settings - Fork 4
/
Copy pathrelease_notes.txt
311 lines (205 loc) · 12.5 KB
/
release_notes.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
Version 5.6
A number of errors in the CO2 line calculation were fixed (E. Mlawer, K.Cady-Pereira)
****************************************************************
Version 5.5
The continuum was updated to MT_CKD_3.5, which includes improvements in the water vapor
continuum from the microwave through the far-infrared (E. Mlawer, V. Payne, J. Mascio, D.
Turner), and a bug fix in the O2 A-Band continuum (E. Mlawer, J. Mascio, E. Magee)
K.E. Cady-Pereira, July 2021
****************************************************************
Version 5.4
The continuum was updated to MT_CKD_3.2, which has new self continnum
coefficients in window regions for wavenumbers greater than 2000 cm-1 and updated self
continuum temperature dependence from 1800-3500 cm-1 (E.J. Mlawer, M.J.
Alvarado, K.E. Cady-Pereira)
Corrected TKC coeffs in the CloudOptProperties routine.
K.E. Cady-Pereira, August 2017
****************************************************************
Version 5.3
The continuum has been updated to MT_CKD v3.0, which included modifications
to the H2O foreign continuum from 0-600 cm-1 and the self continuum in the
microwave that resulted from an analysis of measurements taken at the ARM
RHUBC-II campaign and a re-analysis of RHUBC-I measurements. (E.J. Mlawer,
D.D. Turner, S.N. Paine, V.H. Payne)
Eli Mlawer, November 2016
****************************************************************
Version 5.2
The model for computing cloud liquid water absorption coefficients was replaced.
Prior versions used the model from Liebe, Hufford, and Manabe (1991). This
version uses a new model from Turner, Kneifel, and Cadeddu (2015). The
differences are small for temperatures above 0 deg C with frequencies
below about 60 GHz. Differences may be large at higher frequencies and very
large at lower temperatures. The new and old models now reside in a new
module in CloudOptProp.f90. Subroutine modm uses a generic interface to
obtain the cloud liquid water optical depth from one of the models in
CloudOptProp, and that interface points to the new model by default.
Alan Lipton, AER, June 2015
Fixed bug in reading TAPE3
Karen Cady-Pereira, AER, August 2015
****************************************************************
Version 5.1
Testing MonoRTM_v5.0 desmonstrated that the added capablity functionality to
handle species specific line broadening coefficients significacntly slows the
code down. An additional input parameter (IBRD) was added to make using these
broadening coefficients optional.
CLW was initialized in monortm.f90, to avoid NaNs occuring in some compilers.
lnfl_mod.90 now reads the spectral lines file (TAPE3) starting at 25 cm-1 to
the left of the first requested spectral point, or the beginning of the TAPE3,
if the requested point is within 25 cm-1 of the beginning.
****************************************************************
Version 5.0
The code was significantly restructured, new capabilities were added, and the spectroscopy was upgraded.
* Restructuring (K. Cady-Pereira, G. Uymin, A. Lipton)
- All routines except tips_2003.f are now f90.
- The code's spectroscopic line input structure and atmospheric profiling
code were made more consistent with LBLRTM. Line parameters are now read
from a binary TAPE3 file (as in LBLRTM) produced with MonoLNFL, which is
now included in the MonoRTM package.
- The code to read in and store the spectroscopic data was removed from modm
and is in a separate module: lnfl_mod.f90
- The RT codes are also in a new module: RTMmono.f
- Physical constants are all declared in one module, PhysConstants.f90, which
also provides routines to access the values; geophysical parameters in
another similar module, PlanetEarth.f90.
* Additional capabilities
- The capability to utilize a speed-dependent Voigt line shape has been added
using the approach of Boone et al. (2007; 2011) (M. Alvarado).
- The spectral region about line center in which the detailed Humlicek (1982)
method is used to compute the line shape has been extended to provide
greater accuracy (M. Alvarado, E. Mlawer, G. Villanueva).
- The method to compute path lengths in the code's atmospheric module was
changed to provide greater stability for cases with exceptionally high
rates of change of refractive index with height (M. Alvarado, E. Mlawer, D.
Turner, N. Miller)
- A number of new input and output options, including optional netcdf output
with spectral layer optical depths, have been added. (K. Cady-Pereira, D.
Berthiaume)
- Mixing ratio inputs are now allowed for IATM=0 (K. Cady-Pereira, J. Delamere)
- The capability to utilize available line broadening coefficients (width,
temperature dependence, pressure shift) that are specific to a given pair
of species was added (K. Cady-Pereira, E. Mlawer, M. Alvarado).
- A bug related to foreign broadening of oxygen transitions was fixed (E.
Mlawer, M. Alvarado, K. Cady-Pereira).
- A bug related to the use of the continuum in MonoRTM for near-IR cases was
fixed (K. Cady-Pereira, M. Alvarado).
* Spectroscopy
- The default microwave line parameter files,
spectral_lines.dat.0_55.v5.0_fast and spectral_lines.dat.0_55.v5.0_veryfast,
now have a direct correspondence to the full AER linelist, whose current
version is aer_v_3.3 (M. Alvarado, K. Cady-Pereira, E. Mlawer).
- Numerous lines were added to the default microwave line files so that the
calculational accuracy at any frequency between 0 and 899.4 GHz (0-30 cm-1)
with respect to the full line list aer_v_3.3 is:
# for spectral_lines.dat.0_55.v5.0_fast (corresponds to ISPD=0 in MonoRTM
v4.2 and older): 0.1 K for upwelling, 0.2 K for downwelling
# for spectral_lines.dat.0_55.v5.0_veryfast (corresponds to ISPD=1 in MonoRTM
v4.2 and older): 0.5 K for upwelling, 1.0 K for downwelling
(M. Alvarado, E. Mlawer, K. Cady-Pereira)
NOTE: Users who wish to run MonoRTM v5.0 in spectral regions other than the MW
should use the full AER line file (either aer_v_3.2 or aer_v_3.3),
keeping in mind that the full line file can take a long time to run.
- Line parameters were taken from HITRAN 2012 with the exceptions noted below.
1. 60 GHz O2 lines and 120 Ghz O2 line from Tretyakov et al. (2005), as
implemented in MonoRTM v4.2.
2. 0 cm-1 "Debye line" for O2 same as in MonoRTM v4.2, all other O2 lines
below 1.497951 cm-1 removed.
3. The intensities for the H2O lines at 0.7417 cm-1 (22.233 GHz), 6.1145
cm-1 (183.3 GHz), 10.84 cm-1 (325 GHz) and 12.68 cm-1 (380 GHz) are based on the
work of S. A. Clough (1973) and are the same as in MonoRTM v4.2.
4. The foreign widths of the 22 and 183 GHz water vapor lines were
rederived based on HITRAN 2012 line parameters using the approach of Payne et
al. (2009). The temperature dependence parameters for these lines were adjusted
from their HITRAN 2012 values to provide better agreement with calculations by
Gamache (V. Payne, B. Gamache, E. Mlawer).
- Broadening parameters were implemented for the following pairs of molecules:
1. Oxygen transitions broadened by water vapor based on Drouin et al.
(2013) (E. Mlawer, K. Cady-Pereira)
2. Carbon dioxide transitions broadened by water vapor based on
Sung (2009) (K. Cady-Pereira).
3. Water vapor transitions broadened by carbon dioxide based on
calculations by R. Gamache of U. Mass. Lowell (K. Cady-Pereira).
4. Carbon dioxide transitions broadened by carbon dioxide based on
calculations by R. Gamache of U. Mass. Lowell (K. Cady-Pereira).
- The continuum was updated to MT_CKD_2.5.
- Speed dependent parameters were implemented for CO2 transitions in the
bands 68<-1 and 71<-1 (i.e., 30012<-00001 and 30013<-00001) following Devi
et al. (2007a,b) (M. Alvarado).
Karen Cady-Pereira, AER, December 2013
****************************************************************
Version 4.3
This version of MonoRTM includes the MT_CKD 2.5.2 continuum (updated from
MT_CKD 2.4). This continuum update includes a bug fix to the N2 continuum.
Note that versions 4.0 onwards of MonoRTM represent a significant update
to previous versions where the version number begins with 3 or below.
The code has been updated to allow the use of MonoRTM beyond the
microwave region (provided an appropriate spectral line file is used).
A number of changes were also made in order to make the input
more consistent with that of LBLRTM. Note that the INP option is no
longer available. The INP=1 option can be reproduced by setting IATM=1.
The INP=3 option may be reproduced by setting IATM=0. The INP=2 option
is no longer available. Users wishing to run multiple profiles may now
do so by providing multiple profiles in the MONORTM.IN (for IATM=1) or
MONORTM_PROF.IN (for IATM=0) files.
Vivienne Payne, AER Inc., March 2011
****************************************************************
MONORTM_v4.2
An error related to the print-out of total optical depths in the
MONORTM.OUT file was corrected.
****************************************************************
MONORTM_v4.1
Code is now using MT_CKD_2.4 continuum, which includes significant updates to
the self- and foreign-broadened water vapor continuum in the range 0 to 600
cm-1 (0 to 18 THz), based on new analyses of ARM measurements in the microwave
and far-IR regions. (Payne et al., 2011; Delamere et al., 2010).
An error related to calculations for multiple profiles was corrected.
Code has been modified to pass optical depth arrays between subroutines as
arguments in order to improve modularity of the Monochromatic Optical Depth
Model (MODM) module. In addition, the IOD option may now be used as a flag to
output layer optical depths to ascii files.
****************************************************************
MONORTM_v4.0
Code has been updated to allow monochromatic calculations at frequencies
beyond the microwave region. These updates include the implementation of CO2
line coupling and the option to include cross-section molecules.
Format of output files has been modified to accommodate this change.
Calculation of the total internal partition sum has been updated to be
consistent with the calculation in LBLRTM.
MonoRTM now uses MT_CKD_2.1 continuum (previously was using CDK_2.4).
An error in the nitrogen continuum has been corrected.
The INP option has been replaced by the use of IATM=1 or IATM=0 (consistent
with LBLRTM). A stand-alone IDL program is provided to convert ARM netCDF
profiles into MONORTM input format.
****************************************************************
MONORTM_v3.3
Directory structure has been changed to make it more consistent with LBLRTM
The 22GHz and the 183GHz water vapor lines have been updated (Payne et al, 2008)
The 325 GHz water vapor line has been updated to reflect CRB calculations by
Gamache
The 380 GHz water vapor line has been updated according to measurements by
Koshelev et al (2007)
Corrected error in surface reflectance code
Updated limb radiative transfer code
****************************************************************
MONORTM_v3.0
Code has been updated to allow scaling of profiles
Spectral line file has been modified to include new oxygen line widths and
line-coupling coefficients from Tretyakov et al (2005)
More lines in the spectral line file are now included in the fast option, to
increase accuracy at higher frequencies and lower water vapor amounts
****************************************************************
MONORTM_v2.20
Code has been restructured and made more robust
New makefiles allow for the creation of single and double precision code on
SGIs and on MacOSX
****************************************************************
MONORTM_v2.12
A new LBLATM module has been added, which is consistent with the LBLATM module
currently used by LBLRTM
Several minor coding inconsistencies, which led to compilation errors under
some compilers, have been eliminated
****************************************************************
MONORTM_v2.11
O2 line coupling parameters have been modified to yield significantly better
agreement with MWRP measurements in the 50-60 GHz range
Code output contains more detailed information on the current version of the
software and the spectral lines file