General Scheme

[Magic Number][Packet ID][Packet Type][Data]

Magic Number is just 42

Packet ID increment individually on each side and rolls over to 0 when going over 255

Gateway -> Water System

Packet Type Name Anatomy Description / Comment
0 Current Time [1 byte Packet ID of 230 time req] [UNIX Timestamp 32bit] yes Y2K38, i'll just add the 60-something years when it rolls over to 1970
1 Add Water to Irrigate [1 byte Packet ID of challange] [Liters 2 bytes] [Auth Response 32 bytes]
2 Cancel Irrigation [1 byte Packet ID of challange] [Auth Response 32 bytes]
3 Set Irrigation Timer [1 byte Packet ID of challange] [Hour 1 byte] [Minute 1 byte] [Liters 2 bytes] [Auth Response 32 bytes]
241 Reboot Notification No Data Packet sent once on boot
250 Ask for Auth challange No Data
251 Ping
252 Check Auth [1 byte Packet ID of challange] [Auth Response 32 bytes] Debug command to see if you have the right key without doing sth
255 ACK [Packet ID]

Water System -> Gateway

Packet Type Name Anatomy Description / Comment
0 System Status [4+4 bit status] [2 byte fixed point battery voltage] Used to broadcast system state like STATUS_IDLE. Left 4 bits are system state, right 4 ones are more info (for ex in idle: alread watered, turned off, etc). fixed point battery voltage is a uint16_t divided by 100. max value would be 65.535V
1 Watering State [4+4 bit status] [2 byte unsigned int: liters left] [2 byte unsigned int: liters called] broadcasts watering state if currently watering
230 Request Time No Data
240 Reboot Notification No Data Packet sent once on boot
249 ACK [1 byte packet ID]
250 Auth challange [1 byte Packet ID of 250 ask] [Auth challange 16 bytes]
251 No Challange [1 byte Packet ID] Ask for a Challange Fist
253 Commands disabled [1 byte Packet ID]
254 Command Not Authenticated [1 byte Packet ID]
255 Command OK [1 byte Packet ID]

Ground Sensor -> Water System

JUST AN IDEA. PROBABLY WON'T HAPPEN

Packet Type Name Anatomy Description / Comment
100 Ground Data [Sensor ID 1 byte] [Wetness 1 byte] ground wetness is 0%-100% in 0.5% steps (so 0-200 in the wetness byte)

broadcast

  • Broadcast packets are removed from queue after they get acknowledged by the gateway or after 5 retransmits (spaced 5 seconds apart)

system status

0bLLLLRRRR

Left

Bits State
0000 Idle
0001 Pumping
0010 Emptying
0011 Afterdrain
0100 NO WATER
0101 LOW BATTERY
0110 NO TIME
0111 GENERAL FAIL

Right

Idle

Bits Extra
0000 Normal
0001 Off
0010 Done Today
0011 Rain

General Fail

[] = 1 bit, each can be set individually

[Tank Sensors][RTC Missing][RTC Unset][Unused]

(probably insecure) Authentication

  1. User saves 16 byte password from Water Systems Serial Console into the Gateway and requests an action.
  2. Gateway attempts up to 5 times to request an auth challange
  3. Water System respondes with a 16 byte random value as a challange.
  4. Gateway appends puts challange pass and packet data into sha-256 ([chal][pass][packet type][data] -> sha256)
  5. Gateway transmits the command id and parameters followed by the 32 bytes of the sha-256 hash
  6. arduino performs the same sha256 on challange value + security key and checks if they are identical
  7. command is accepted or rejected depending on hashes matching or not