This is the official repository for the paper "Radiologist-in-the-Loop Self-Training for Generalizable CT Metal Artifact Reduction". [arxiv, tmi]
- RISE-MAR Framework: A semi-supervised learning framework that ensures high-quality pseudo groundtruths for clinical CT metal artifact reduction (MAR).
- Clinical Quality Assessor (CQA): A pretrained model that evaluates the quality of CT images potentially affected by metal artifacts
- Preprint released
- Core model implementation
- Training code available
- CQA model weights
To implement the full version of RISE-MAR, follow these steps:
- Download relevant CT datasets
- Simulate metal artifact-affected data to construct paired data
- Organize data using JSON metadata files
Paired Data Example (please see ./data/meta/example_paired_deepl.json
):
{
"case_001": {
"metal_img": "path/to/artifact_affected_image",
"li_img": "path/to/LI_corrected_image",
"gt_img": "path/to/artifact_free_ground_truth",
"metal_mask": "path/to/metal_mask",
"root_dir": "optional/path/prefix"
},
// Additional cases...
}
UnPaired Data Example (please see ./data/meta/example_unpaired_deepl.json
):
{
"ma": { // Metal artifact-affected images
"case_001": {
"img": "path/to/artifact_affected_image",
"quality": 5, // For CQA model training, optional
"root_dir": "optional/path/prefix"
},
// Additional cases...
},
"mf": { // Metal artifact-free images
"case_001": {
"img": "path/to/artifact_free_image",
"quality": 9,
"root_dir": "optional/path/prefix"
},
// Additional cases...
}
}
After preparation, browse ./configs/__init__.py
and update the paths for the metadata.
We refer to "baseline models" as models that produce imperfect prediction for clinical MAR. These models can be obtained from:
- Some conventional methods (e.g., LI, NMAR, ...)
- Insufficient training (e.g., early stop before model convergence)
- Models with limited domain transferability (e.g., can handle simulated metal artifacts very well but perform poor MAR on real data)
- ...
Turns out that they are still useful! In our work, they:
- serve as undertrained MAR models that provide CT images with low-to-moderate quality, greatly enhancing the diversity of our clinical quality assessment dataset.
- provide better network initialization, which often leads to a more stable training process for unsupervised or semisupervised methods.
- serve as the prior model, i.e., teacher network in our paper. A stronger prior model certainly perform better MAR, but with our RISE-MAR framework, we can still employ an imperfect one while expecting satisfactory MAR results ;)
- ...
As an example of training script, please run:
bash scripts/train_supervised_mar.sh
Once the baseline models are prepared, configure related paths (UNDETRAINED_WEIGHTS
and PRETRAINED_*
) in ./configs/__init__.py
.
Adjust the arguments in scripts/train_cqa.sh
and run the training script:
bash scripts/train_cqa.sh
Update the path to the CQA model weights (PRETRAINED_CQA_PATH
) in ./configs/__init__.py
after training.
Adjust the arguments in scripts/train_risemar.sh
and run the training script:
bash scripts/train_risemar.sh
If you find our work and code helpful, please kindly cite our paper 💙
@ARTICLE{ma2025risemar,
author={Ma, Chenglong and Li, Zilong and Li, Yuanlin and Han, Jing and Zhang, Junping and Zhang, Yi and Liu, Jiannan and Shan, Hongming},
journal={IEEE Transactions on Medical Imaging},
title={Radiologist-in-the-Loop Self-Training for Generalizable {CT} Metal Artifact Reduction},
year={2025},
volume={},
number={},
pages={1-1},