version: '3.8'
services:
# Mosquitto MQTT Broker
mosquitto:
container_name: smartmeter_mosquitto
image: eclipse-mosquitto
ports:
- $mosquittoPort:1883
- '9001:9001'
restart: unless-stopped
volumes:
- './config/mosquitto.conf:/mosquitto/config/mosquitto.conf'
networks:
- smartmeterNetwork
# InfluxDB for Storing data
influxdb:
container_name: smartmeter_influxdb
image: 'influxdb:1.8'
restart: unless-stopped
ports:
- $influxPort:8086
volumes:
- $PWD/data/influxDB:/var/lib/influxdb
environment:
- INFLUXDB_DATA_ENGINE=tsm1
- INFLUXDB_REPORTING_DISABLED=false
- INFLUXDB_ADMIN_USER=${influxdbAdminUser}
- INFLUXDB_ADMIN_PASSWORD=${influxdbAdminPassword}
- INFLUXDB_USER=${influxdbUser}
- INFLUXDB_USER_PASSWORD=${influxdbUserPassword}
- INFLUXDB_DB=${influxdbDatabase}
- INFLUXDB_HTTP_LOG_ENABLED=false
- INFLUXDB_META_LOGGING_ENABLED=false
- INFLUXDB_DATA_QUERY_LOG_ENABLED=false
- INFLUXDB_LOGGING_LEVEL=warn
- TZ=Europe/Berlin
networks:
- smartmeterNetwork
# Grafana for Visualizing data
grafana:
container_name: smartmeter_grafana
image: grafana/grafana:10.0.3
ports:
- $grafanaPort:3000
user: "1000"
restart: unless-stopped
environment:
- GF_SECURITY_ADMIN_PASSWORD=$grafanaRootPassword
- influxdbUser=$influxdbUser
volumes:
- $PWD/data/grafana:/var/lib/grafana
- $PWD/config/grafana_datasource.yml:/etc/grafana/provisioning/datasources/automatic.yml
- $PWD/config/grafana_dashboard.yml:/etc/grafana/provisioning/dashboards/default.yml
networks:
- smartmeterNetwork
# NodeRed for automatic insertion into db
node_red:
container_name: smartmeter_node_red
build:
context: .
dockerfile: Dockerfile-NodeRed
restart: unless-stopped
depends_on:
- mosquitto
- influxdb
ports:
- $nodeRedPort:1880
volumes:
- $PWD/data/nodeRed:/data
networks:
- smartmeterNetwork
# Python SmartMeter reader Script
reader:
container_name: smartmeter_pyreader
depends_on:
- mosquitto
build:
context: .
privileged: true # needed for accessing usb
restart: unless-stopped
environment:
- COMPORT=/dev/ttyUSB0
- KEY=$ReaderKey
- LOG_LEVEL=1 # 0 - nothing; 1 - only debug; 2 - debug and data
- USE_MQTT=True
- MQTT_BROKER=mosquitto
- MQTT_PORT=$mosquittoPort
# - MQTT_USER=
# - MQTT_PASSWORD=
networks:
- smartmeterNetwork
networks:
smartmeterNetwork:
driver: bridge
external: true