From faa3a14843991e2d11391fc01c1329c61f52730c Mon Sep 17 00:00:00 2001 From: Erwan MATHIEU Date: Tue, 22 Oct 2024 09:27:43 +0200 Subject: [PATCH] Restore temperature wait for UM Original printers CURA-12174 This is apparently required for those printers. The default behavior was changed in previous release, and not having the wait temperature prevented them for setting the initial temperature. I assume they don't recognize the M104 command --- resources/definitions/ultimaker_original.def.json | 1 + 1 file changed, 1 insertion(+) diff --git a/resources/definitions/ultimaker_original.def.json b/resources/definitions/ultimaker_original.def.json index e7870129ed9..826a612c6c6 100644 --- a/resources/definitions/ultimaker_original.def.json +++ b/resources/definitions/ultimaker_original.def.json @@ -68,6 +68,7 @@ "machine_start_gcode": { "default_value": "G21 ;metric values\nG90 ;absolute positioning\nM82 ;set extruder to absolute mode\nM107 ;start with the fan off\nG28 X0 Y0 ;move X/Y to min endstops\nG28 Z0 ;move Z to min endstops\nG1 Z15.0 F9000 ;move the platform down 15mm\nG92 E0 ;zero the extruded length\nG1 F200 E6 ;extrude 6 mm of feed stock\nG92 E0 ;zero the extruded length again\nG1 Y50 F9000\n;Put printing message on LCD screen\nM117 Printing..." }, "machine_use_extruder_offset_to_offset_coords": { "default_value": true }, "machine_width": { "default_value": 205 }, + "material_print_temp_wait": { "value": true }, "speed_slowdown_layers": { "value": 2 } } } \ No newline at end of file