You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
The internal GmiiBus interface as used in RgmiiToGMIIBridge has a clock enable and is not strictly compliant with standard GMII. Need to add proper GMII support so we can use it for Zynq EMIO GMII-RGMII bridging.
The text was updated successfully, but these errors were encountered:
The internal GmiiBus interface as used in RgmiiToGMIIBridge has a clock enable and is not strictly compliant with standard GMII. Need to add proper GMII support so we can use it for Zynq EMIO GMII-RGMII bridging.
The text was updated successfully, but these errors were encountered: