Notifications
You must be signed in to change notification settings - Fork 12
/
deye-seplosV3.yaml
1906 lines (1746 loc) · 53.4 KB
/
deye-seplosV3.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
esphome:
name: deye-seplos_v3
friendly_name: deye-seplos_v3
esp32:
board: az-delivery-devkit-v4
framework:
type: esp-idf
substitutions:
bms_name: seplos-bms
modbus_update_interval: "10s"
settings_skipped_updates: "10"
query_throttle: "50ms"
device_name: deye
device_type: sun10k
device_description: "Esphome component for Deye sun-10k-sg04lp3"
modbus_controller_id: sg04lp3
external_components_source1: github://syssi/esphome-seplos-bms@main
# Enable logging
logger:
level: INFO
# Enable Home Assistant API
api:
encryption:
key: "..."
ota:
- platform: esphome
password: "..."
wifi:
ssid: !secret wifi_ssid
password: !secret wifi_password
# Enable fallback hotspot (captive portal) in case wifi connection fails
ap:
ssid: "Deye-Seplos-Neey"
password: "kL3kAio4DeDb"
mqtt:
broker: 192.168.1.1
port: 1883
topic_prefix: deye10k
username: username
password: password
time:
- platform: sntp
id: sntp_time
timezone: Europe/Berlin
servers:
- pool.ntp.org
captive_portal:
external_components:
- source: ${external_components_source1}
refresh: 0s
uart:
- id: uartdeye
tx_pin: 27
rx_pin: 26
baud_rate: 9600
- id: uartseplos
tx_pin: 17
rx_pin: 16
baud_rate: 19200
debug:
direction: BOTH
dummy_receiver: false
modbus_controller:
- id: ${modbus_controller_id}
address: 0x01
modbus_id: modbus1
setup_priority: -10
update_interval: ${modbus_update_interval}
command_throttle: ${query_throttle}
- id: bms0
address: 0x00
modbus_id: modbus0
command_throttle: 200ms
update_interval: 10s
modbus:
- id: modbus1
uart_id: uartdeye
- id: modbus0
uart_id: uartseplos
send_wait_time: 200ms
sensor:
- platform: template
name: "${device_type}-PV Total Power"
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
lambda: |-
return (int)((id(${device_type}_PV1_Power).state + id(${device_type}_PV2_Power).state));
update_interval: 10s
- platform: modbus_controller #${device_type}-køleplade temeratur
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Heat sink temperature"
id: ${device_type}_koleplade_temeratur
register_type: holding
address: 541
unit_of_measurement: "°C"
value_type: S_WORD
accuracy_decimals: 2
filters:
- offset: -1000
- multiply: 0.1
- platform: modbus_controller #${device_type}-load frequency
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-load frequency"
id: ${device_type}_load_frequency
register_type: holding
address: 655
unit_of_measurement: "Hz"
state_class: "measurement"
accuracy_decimals: 2
filters:
- multiply: 0.01
value_type: U_WORD
- platform: modbus_controller #${device_type}-inverter-frequency
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-inverter-frequency"
id: ${device_type}_inverter_frequency
register_type: holding
address: 638
unit_of_measurement: "Hz"
state_class: "measurement"
accuracy_decimals: 2
filters:
- multiply: 0.01
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-PV1 Power"
id: ${device_type}_PV1_Power
register_type: holding
address: 672
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-PV2 Power"
id: ${device_type}_PV2_Power
register_type: holding
address: 673
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-PV1 Voltage"
id: ${device_type}_PV1_Voltage
register_type: holding
address: 676
unit_of_measurement: "V"
state_class: "measurement"
accuracy_decimals: 0
filters:
- multiply: 0.1
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-PV2 Voltage"
id: ${device_type}_PV2_Voltage
register_type: holding
address: 678
unit_of_measurement: "V"
state_class: "measurement"
accuracy_decimals: 0
filters:
- multiply: 0.1
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-PV1 Current"
id: ${device_type}_PV1_Current
register_type: holding
address: 677
unit_of_measurement: "A"
state_class: "measurement"
accuracy_decimals: 1
filters:
- multiply: 0.1
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-PV2 Current"
id: ${device_type}_PV2_Current
register_type: holding
address: 679
unit_of_measurement: "A"
state_class: "measurement"
accuracy_decimals: 1
filters:
- multiply: 0.1
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Daily Production"
id: ${device_type}_Daily_Production
register_type: holding
address: 529
unit_of_measurement: "kWh"
state_class: "total_increasing"
device_class: energy
accuracy_decimals: 1
filters:
- multiply: 0.1
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Total PV Production" #Cumulative Production
id: ${device_type}_Total_PV_Production
register_type: holding
address: 534
unit_of_measurement: "kWh"
state_class: "measurement"
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Total Grid Power" # Grid side total power
id: ${device_type}_Total_Grid_Power
register_type: holding
address: 625
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
value_type: S_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Daily Energy Bought"
id: ${device_type}_Daily_Energy_Bought
register_type: holding
address: 520
unit_of_measurement: "kWh"
state_class: "total_increasing"
device_class: energy
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Daily Energy Sold"
id: ${device_type}_Daily_Energy_Sold
register_type: holding
address: 521
unit_of_measurement: "kWh"
state_class: "total_increasing"
device_class: energy
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Total Energy Bought"
id: ${device_type}_Total_Energy_Bought
register_type: holding
address: 522
unit_of_measurement: "kWh"
# state_class: "total_increasing"
state_class: "measurement"
device_class: energy
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Total Energy Sold"
id: ${device_type}_Total_Energy_Sold
register_type: holding
address: 524
unit_of_measurement: "kWh"
state_class: "total_increasing"
device_class: energy
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller #Total Consumption
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Total Consumption"
id: ${device_type}_Total_Consumption
register_type: holding
address: 527
unit_of_measurement: "kWh"
state_class: "total_increasing"
device_class: energy
accuracy_decimals: 2
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-active power generation of today"
id: ${device_type}_active_power_generation_of_today
register_type: holding
address: 502
unit_of_measurement: "kWh"
state_class: "total_increasing"
device_class: energy
accuracy_decimals: 1
value_type: S_WORD
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Load Energy today"
id: ${device_type}_load_energy_today
register_type: holding
address: 526
unit_of_measurement: "kWh"
# state_class: "total_increasing"
state_class: "measurement"
device_class: energy
accuracy_decimals: 1
value_type: S_WORD
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Total Load Energy"
id: ${device_type}_total_load_energy
register_type: holding
address: 527
unit_of_measurement: "kWh"
# state_class: "total_increasing"
state_class: "measurement"
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
# value_type: S_WORD
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Grid Current L1"
id: ${device_type}_Grid_Current_L1
register_type: holding
address: 630
unit_of_measurement: "A"
state_class: "measurement"
accuracy_decimals: 1
filters:
- multiply: 0.01
value_type: S_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Grid Current L2"
id: ${device_type}_Grid_Current_L2
register_type: holding
address: 631
unit_of_measurement: "A"
state_class: "measurement"
accuracy_decimals: 1
filters:
- multiply: 0.01
value_type: S_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Grid Current L3"
id: ${device_type}_Grid_Current_L3
register_type: holding
address: 632
unit_of_measurement: "A"
state_class: "measurement"
accuracy_decimals: 1
filters:
- multiply: 0.01
value_type: S_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Grid Voltage L1"
id: ${device_type}_Grid_Voltage_L1
register_type: holding
address: 598
unit_of_measurement: "V"
state_class: "measurement"
accuracy_decimals: 0
filters:
- multiply: 0.1
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Grid Voltage L2"
id: ${device_type}_Grid_Voltage_L2
register_type: holding
address: 599
unit_of_measurement: "V"
state_class: "measurement"
accuracy_decimals: 0
filters:
- multiply: 0.1
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Grid Voltage L3"
id: ${device_type}_Grid_Voltage_L3
register_type: holding
address: 600
unit_of_measurement: "V"
state_class: "measurement"
accuracy_decimals: 0
filters:
- multiply: 0.1
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Internal CT L1 Power"
id: ${device_type}_Internal_CT_L1_Power
register_type: holding
address: 604
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
value_type: S_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Internal CT L2 Power"
id: ${device_type}_Internal_CT_L2_Power
register_type: holding
address: 605
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
value_type: S_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Internal CT L3 Power"
id: ${device_type}_Internal_CT_L3_Power
register_type: holding
address: 606
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
value_type: S_WORD
- platform: modbus_controller # Grid internal - total active power
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Internal total Power"
id: ${device_type}_Internal_total_Power
register_type: holding
address: 607
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
value_type: S_WORD
- platform: modbus_controller # Grid Current L1
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Out of Grid Current L1"
id: ${device_type}_Out_of_Grid_Current_L1
register_type: holding
address: 613
unit_of_measurement: "A"
state_class: "measurement"
accuracy_decimals: 2
filters:
- multiply: 0.01
value_type: S_WORD
- platform: modbus_controller # Grid Current L2
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Out of Grid Current L2"
id: ${device_type}_Out_of_Grid_Current_L2
register_type: holding
address: 614
unit_of_measurement: "A"
state_class: "measurement"
accuracy_decimals: 2
filters:
- multiply: 0.01
value_type: S_WORD
- platform: modbus_controller # Grid Current L3
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Out of Grid Current L3"
id: ${device_type}_Out_of_Grid_Current_L3
register_type: holding
address: 615
unit_of_measurement: "A"
state_class: "measurement"
accuracy_decimals: 2
filters:
- multiply: 0.01
value_type: S_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-External CT L1 Power"
id: ${device_type}_External_CT_L1_Power
register_type: holding
address: 616
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
value_type: S_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-External CT L2 Power"
id: ${device_type}_External_CT_L2_Power
register_type: holding
address: 617
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
value_type: S_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-External CT L3 Power"
id: ${device_type}_External_CT_L3_Power
register_type: holding
address: 618
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
value_type: S_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Out-of-grid–total power"
id: ${device_type}_out_of_grid_total_power
register_type: holding
address: 619
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
value_type: S_WORD
- platform: modbus_controller # Load totalpower
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Load totalpower"
id: ${device_type}_Load_totalpower
register_type: holding
address: 653
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
value_type: S_WORD
- platform: modbus_controller # Load totalpower
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Generator totalpower"
id: ${device_type}_Generator_totalpower
register_type: holding
address: 667
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
value_type: S_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Warning1"
id: ${device_type}_Warning1
register_type: holding
address: 553
accuracy_decimals: 0
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Warning2"
id: ${device_type}_Warning2
register_type: holding
address: 554
accuracy_decimals: 0
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Warning3"
id: ${device_type}_Warning3
register_type: holding
address: 555
accuracy_decimals: 0
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Error1"
id: ${device_type}_Error1
register_type: holding
address: 556
accuracy_decimals: 0
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Error2"
id: ${device_type}_Error2
register_type: holding
address: 557
accuracy_decimals: 0
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Error3"
id: ${device_type}_Error3
register_type: holding
address: 558
accuracy_decimals: 0
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Failure status of communication board"
id: ${device_type}_Failure_status_of_communication_board
register_type: holding
address: 548
accuracy_decimals: 0
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Minimum insulation impedance"
id: ${device_type}_Minimum_insulation_impedance
register_type: holding
unit_of_measurement: "kΩ"
state_class: "measurement"
address: 65
accuracy_decimals: 0
value_type: U_WORD
filters:
- multiply: 0.1
# Batterie
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Today charge of the battery"
id: ${device_type}_Today_charge_of_the_battery
register_type: holding
address: 514
unit_of_measurement: "kWh"
state_class: "total_increasing"
device_class: energy
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Today discharge of the battery"
id: ${device_type}_Today_discharge_of_the_battery
register_type: holding
address: 515
unit_of_measurement: "kWh"
state_class: "total_increasing"
device_class: energy
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
skip_updates: 5
name: "${device_type}-Total charge of the battery"
id: ${device_type}_battery_total_charge
register_type: holding
address: 516
unit_of_measurement: "kWh"
state_class: "total_increasing"
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
skip_updates: 5
name: "${device_type}-Total discharge of the battery"
id: ${device_type}_battery_total_discharge
register_type: holding
address: 518
unit_of_measurement: "kWh"
state_class: "total_increasing"
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-battery temperature"
id: ${device_type}_battery_temperature
register_type: holding
address: 586
unit_of_measurement: "°C"
accuracy_decimals: 1
value_type: U_WORD
filters:
- offset: -1000
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-battery voltage"
id: ${device_type}_battery_voltage
register_type: holding
address: 587
unit_of_measurement: "V"
state_class: "measurement"
accuracy_decimals: 2
filters:
- multiply: 0.01
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-battery capacity"
id: ${device_type}_battery_capacity
register_type: holding
address: 588
unit_of_measurement: "%"
state_class: "measurement"
accuracy_decimals: 1
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Battery output power"
id: ${device_type}_Battery_output_power
register_type: holding
address: 590
unit_of_measurement: "W"
state_class: "measurement"
accuracy_decimals: 0
value_type: S_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-Battery output current"
id: ${device_type}_Battery_output_current
register_type: holding
address: 591
unit_of_measurement: "A"
state_class: "measurement"
accuracy_decimals: 2
filters:
- multiply: 0.01
value_type: S_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${device_type}-The corrected capacity of the battery"
id: ${device_type}_The_corrected_capacity_of_the_battery
register_type: holding
address: 592
unit_of_measurement: "Ah"
state_class: "measurement"
accuracy_decimals: 0
value_type: U_WORD
# 1000 Pack Voltage R UINT16 2 10mV
- platform: modbus_controller
modbus_controller_id: bms0
name: "${bms_name} total voltage"
address: 0x1000
register_type: read
value_type: U_WORD
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
accuracy_decimals: 2
filters:
- multiply: 0.01
# 1001 Current R INT16 2 10mA
- platform: modbus_controller
modbus_controller_id: bms0
name: "${bms_name} current"
address: 0x1001
register_type: read
value_type: S_WORD
unit_of_measurement: "A"
device_class: current
state_class: measurement
accuracy_decimals: 2
filters:
- multiply: 0.01
# 1002 Remaining capacity R UINT16 2 10mAH
- platform: modbus_controller
modbus_controller_id: bms0
name: "${bms_name} remaining capacity"
address: 0x1002
register_type: read
value_type: U_WORD
unit_of_measurement: "Ah"
state_class: measurement
accuracy_decimals: 2
filters:
- multiply: 0.01
# 1003 Total Capacity R UINT16 2 10mAH
- platform: modbus_controller
modbus_controller_id: bms0
name: "${bms_name} total capacity"
address: 0x1003
register_type: read
value_type: U_WORD
unit_of_measurement: "Ah"
state_class: measurement
accuracy_decimals: 2
filters:
- multiply: 0.01
# 1004 Total Discharge Capacity R UINT16 2 10AH
- platform: modbus_controller
modbus_controller_id: bms0
name: "${bms_name} total discharge capacity"
address: 0x1004
register_type: read
value_type: U_WORD
unit_of_measurement: "Ah"
state_class: measurement
accuracy_decimals: 2
filters:
- multiply: 0.01
# 1005 SOC R UINT16 2 0.1%
- platform: modbus_controller
modbus_controller_id: bms0
name: "${bms_name} state of charge"
address: 0x1005
register_type: read
value_type: U_WORD
unit_of_measurement: "%"
device_class: battery
state_class: measurement
accuracy_decimals: 0
filters:
- multiply: 0.1
# 1006 SOH R UINT16 2 0.1%
- platform: modbus_controller
modbus_controller_id: bms0
name: "${bms_name} state of health"
address: 0x1006
register_type: read
value_type: U_WORD
unit_of_measurement: "%"
state_class: measurement
accuracy_decimals: 0
# 1007 Cycle R UINT16 2 1
- platform: modbus_controller
modbus_controller_id: bms0
name: "${bms_name} cycle"
address: 0x1007
register_type: read
value_type: U_WORD
unit_of_measurement: ""
state_class: measurement
accuracy_decimals: 0
# 1008 Averag of Cell Votage R UINT16 2 1mV
- platform: modbus_controller
modbus_controller_id: bms0
name: "${bms_name} average cell voltage"
address: 0x1008
register_type: read
value_type: U_WORD
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
accuracy_decimals: 3
filters:
- multiply: 0.001
# 1009 Averag of Cell Temperature R UINT16 2 0.1K
- platform: modbus_controller
modbus_controller_id: bms0
name: "${bms_name} average cell temperature"
address: 0x1009
register_type: read
value_type: S_WORD
unit_of_measurement: "°C"
device_class: temperature
state_class: measurement
accuracy_decimals: 1
filters:
- offset: -2731.5
- multiply: 0.1
# 100A Max Cell Voltage R UINT16 2 1mV
- platform: modbus_controller
modbus_controller_id: bms0
name: "${bms_name} max cell voltage"
address: 0x100A
register_type: read
value_type: U_WORD
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
accuracy_decimals: 3
filters:
- multiply: 0.001
# 100B Min Cell Voltage R UINT16 2 1mV
- platform: modbus_controller
modbus_controller_id: bms0
name: "${bms_name} min cell voltage"
address: 0x100B
register_type: read
value_type: U_WORD
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
accuracy_decimals: 3
filters:
- multiply: 0.001
# 100C Max Cell Temperature R UINT16 2 0.1K
- platform: modbus_controller
modbus_controller_id: bms0
name: "${bms_name} max cell temperature"
address: 0x100C
register_type: read
value_type: S_WORD
unit_of_measurement: "°C"
device_class: temperature
state_class: measurement
accuracy_decimals: 1
filters:
- offset: -2731.5
- multiply: 0.1
# 100D Min Cell Temperature R UINT16 2 0.1K
- platform: modbus_controller
modbus_controller_id: bms0
name: "${bms_name} min cell temperature"
address: 0x100D
register_type: read
value_type: S_WORD
unit_of_measurement: "°C"
device_class: temperature
state_class: measurement
accuracy_decimals: 1
filters: