See usage instructions for more options and info.
In case of using parametric equalizer, apply preamp of -6.2dB and build filters manually with these parameters. The first 5 filters can be used independently. When using independent subset of filters, apply preamp of -6.2dB.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 77 Hz | 1.33 | -4.7 dB |
Peaking | 264 Hz | 1.22 | -6.1 dB |
Peaking | 2051 Hz | 2.25 | 4.7 dB |
Peaking | 4920 Hz | 2.51 | 5.4 dB |
Peaking | 20029 Hz | 2.45 | 2.4 dB |
Peaking | 20 Hz | 2.22 | 3.9 dB |
Peaking | 628 Hz | 4.08 | 3.4 dB |
Peaking | 3328 Hz | 6.04 | -3.1 dB |
Peaking | 8611 Hz | 2.57 | 5.1 dB |
Peaking | 13240 Hz | 1 | -3.6 dB |
In case of using fixed band (also called graphic) equalizer, apply preamp of -4.2dB (if available) and set gains manually with these parameters.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 31 Hz | 1.41 | 2.4 dB |
Peaking | 62 Hz | 1.41 | -4.9 dB |
Peaking | 125 Hz | 1.41 | -1.6 dB |
Peaking | 250 Hz | 1.41 | -6.4 dB |
Peaking | 500 Hz | 1.41 | 0.3 dB |
Peaking | 1000 Hz | 1.41 | -0.1 dB |
Peaking | 2000 Hz | 1.41 | 3.4 dB |
Peaking | 4000 Hz | 1.41 | 1.7 dB |
Peaking | 8000 Hz | 1.41 | 3.2 dB |
Peaking | 16000 Hz | 1.41 | -3.6 dB |