Notifications
You must be signed in to change notification settings - Fork 0
/
Copy path08.ehp.csv
We can make this file beautiful and searchable if this error is corrected: It looks like row 2 should actually have 15 columns, instead of 2 in line 1.
328 lines (328 loc) · 45.7 KB
/
08.ehp.csv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,unit,comment
*r,
*u,
*w,
*uw,
*[heatpumptype],,,heatpumptype,,value
*[id_sw],scan,,,,SW
[heatpumptype=3]r,,,SourceTempOutput,OutletTemperature: heat source outlet temperature for water to water machines,,,b509,0d0800,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=3]u,,,SourceTempOutput,OutletTemperature: heat source outlet temperature for water to water machines,,,b509,290800,value,,IGN:2,,,,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=3]r,,,Source,HeatSourcePump WW: Brine_Pump WW,,,b509,0d1900,value,,UCH,0=off;1=on,,
[heatpumptype=3]u,,,Source,HeatSourcePump WW: Brine_Pump WW,,,b509,291900,value,,IGN:2,,,,value,,UCH,0=off;1=on,,
[heatpumptype=3]r,,,Source2Pump,Brine2_P: external Brine or water pump,,,b509,0d1a00,value,,UCH,0=off;1=on,,
[heatpumptype=3]r,,,SourceSwitch,FlowSwitch: water flow switch; 1 = switch has tripped,,,b509,0d2600,value,,UCH,0=ok;1=error,,
[heatpumptype=3]u,,,SourceSwitch,FlowSwitch: water flow switch; 1 = switch has tripped,,,b509,292600,value,,IGN:2,,,,value,,UCH,0=ok;1=error,,
[heatpumptype=3]r,,,CondensorTemp,T_Condensor_WW: Condensor temperature sensor WW,,,b509,0d0d00,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=3]u,,,CondensorTemp,T_Condensor_WW: Condensor temperature sensor WW,,,b509,290d00,value,,IGN:2,,,,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=3]r,,,OverpressureThreshold,Overpressure_WW: limit for compressor high pressure which is considered an overpressure situation (for Water/Water machines),,,b509,0d7701,value,,ULG,,mbar,pressure
[heatpumptype=3]w,,service,OverpressureThreshold,Overpressure_WW: limit for compressor high pressure which is considered an overpressure situation (for Water/Water machines),,,b509,0e7701,value,,ULG,,mbar,pressure
[heatpumptype=3]r,,,DeltaTempT6T7,Delta_T6_T7_WW: Maximum temperature difference between heat source outlet and inlet - WW,,,b509,0d6e00,value,,D2C,,°C,temperature
[heatpumptype=3]w,,install,DeltaTempT6T7,Delta_T6_T7_WW: Maximum temperature difference between heat source outlet and inlet - WW,,,b509,0e6e00,value,,D2C,,°C,temperature
[heatpumptype=3]r,,,SourcePumpPrerunTime,HS_Pump_Prerun_WW: Heat source pump prerun in heat source circuit - WW,,,b509,0d7600,value,,ULG,120,min,minutes
[heatpumptype=3]w,,install,SourcePumpPrerunTime,HS_Pump_Prerun_WW: Heat source pump prerun in heat source circuit - WW,,,b509,0e7600,value,,ULG,120,min,minutes
[heatpumptype=3]r,,,SourceTempOutputOffset,OutletTemperature: Offset for heat source outlet temperature sensor - WW,,,b509,0dc900,value,,D2C,,K,
[heatpumptype=3]w,,install,SourceTempOutputOffset,OutletTemperature: Offset for heat source outlet temperature sensor - WW,,,b509,0ec900,value,,D2C,,K,
[heatpumptype=3]r,,,EvaporatorTemp,T_Condensor_WW: Condensor temperature sensor WW,,,b509,0d0500,value,,D2C,,°C,temperature
[heatpumptype=2]r,,,SourceTempOutput,BrineOutlet: heat source outlet temperature for brine to water machines,,,b509,0d0800,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=2]u,,,SourceTempOutput,BrineOutlet: heat source outlet temperature for brine to water machines,,,b509,290800,value,,IGN:2,,,,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=2]r,,,SourcePress,P_Brine: Brine pressure sensor,,,b509,0d1600,press,,FLT,,bar,pressure,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=2]r,,,Source,HeatSourcePump BW: Brine Pump BW,,,b509,0d1900,value,,UCH,0=off;1=on,,
[heatpumptype=2]u,,,Source,HeatSourcePump BW: Brine Pump BW,,,b509,291900,value,,IGN:2,,,,value,,UCH,0=off;1=on,,
[heatpumptype=2]r,,,SourceSwitch,BrineSwitch: brine pressure switch; 1 = switch has tripped,,,b509,0d2600,value,,UCH,0=ok;1=error,,
[heatpumptype=2]u,,,SourceSwitch,BrineSwitch: brine pressure switch; 1 = switch has tripped,,,b509,292600,value,,IGN:2,,,,value,,UCH,0=ok;1=error,,
[heatpumptype=2]r,,,CondensorTemp,T_Condensor_BW: Condensor temperature sensor BW,,,b509,0d0d00,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=2]u,,,CondensorTemp,T_Condensor_BW: Condensor temperature sensor BW,,,b509,290d00,value,,IGN:2,,,,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=2]r,,,OverpressureThreshold,Overpressure_BW: limit for compressor high pressure which is considered an overpressure situation (for Brine/Water machines),,,b509,0d7701,value,,ULG,,mbar,pressure
[heatpumptype=2]w,,service,OverpressureThreshold,Overpressure_BW: limit for compressor high pressure which is considered an overpressure situation (for Brine/Water machines),,,b509,0e7701,value,,ULG,,mbar,pressure
[heatpumptype=2]r,,,DeltaTempT6T7,Delta_T6_T7_BW: Maximum temperature difference between heat source outlet and inlet - BW,,,b509,0d6e00,value,,D2C,,°C,temperature
[heatpumptype=2]w,,install,DeltaTempT6T7,Delta_T6_T7_BW: Maximum temperature difference between heat source outlet and inlet - BW,,,b509,0e6e00,value,,D2C,,°C,temperature
[heatpumptype=2]r,,,SourceTempOutputT8Min,Einfrierschutz: Minimum heat source outlet temperature BW (equal to WW),,,b509,0d7a01,value,,SCH,,°C,temperature
[heatpumptype=2]w,,install,SourceTempOutputT8Min,Einfrierschutz: Minimum heat source outlet temperature BW (equal to WW),,,b509,0e7a01,value,,SCH,,°C,temperature
[heatpumptype=2]r,,,SourcePumpPrerunTime,HS_Pump_Prerun_BW: Heat source pump prerun in heat source circuit - BW,,,b509,0d7600,value,,ULG,120,min,minutes
[heatpumptype=2]w,,install,SourcePumpPrerunTime,HS_Pump_Prerun_BW: Heat source pump prerun in heat source circuit - BW,,,b509,0e7600,value,,ULG,120,min,minutes
[heatpumptype=2]r,,,FlowtempCoolingMin,MinFlowtempCooling: flow temperature that must be exceeded to start cooling,,,b509,0d7401,value,,UCH,,°C,temperature
[heatpumptype=2]w,,install,FlowtempCoolingMin,MinFlowtempCooling: flow temperature that must be exceeded to start cooling,,,b509,0e7401,value,,UCH,,°C,temperature
[heatpumptype=2]r,,,Bleeding,Initiates and indicates the bleeding function,,,b509,0d1300,value,,UCH,0=no;1=yes,,
[heatpumptype=2]w,,install,Bleeding,Initiates and indicates the bleeding function,,,b509,0e1300,value,,UCH,0=no;1=yes,,
[heatpumptype=2]u,,,Bleeding,Initiates and indicates the bleeding function,,,b509,291300,value,,IGN:2,,,,value,,UCH,0=no;1=yes,,
[heatpumptype=2]r,,,SourceTempOutputOffset,BrineOutlet: Offset for heat source outlet temperature sensor - BW,,,b509,0dc900,value,,D2C,,K,
[heatpumptype=2]w,,install,SourceTempOutputOffset,BrineOutlet: Offset for heat source outlet temperature sensor - BW,,,b509,0ec900,value,,D2C,,K,
[heatpumptype=1]r,,,SourceTempOutput,AirOutlet: heat source outlet temperature for air to water machines,,,b509,0d0800,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=1]u,,,SourceTempOutput,AirOutlet: heat source outlet temperature for air to water machines,,,b509,290800,value,,IGN:2,,,,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=1]r,,,Source,Fan AW,,,b509,0d1900,value,,UCH,0=off;1=on,,
[heatpumptype=1]u,,,Source,Fan AW,,,b509,291900,value,,IGN:2,,,,value,,UCH,0=off;1=on,,
[heatpumptype=1]r,,,SourceSwitch,FanContact: Fan overheat thermostat; 1 = switch has tripped,,,b509,0d2600,value,,UCH,0=ok;1=error,,
[heatpumptype=1]u,,,SourceSwitch,FanContact: Fan overheat thermostat; 1 = switch has tripped,,,b509,292600,value,,IGN:2,,,,value,,UCH,0=ok;1=error,,
[heatpumptype=1]r,,,EvaporatorTemp,T_Evaporator: Internal evaporator temperature sensor,,,b509,0d0500,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=1]r,,,CoolValve,V_Cool: Refrigerant circuit reversion valve,,,b509,0d1c00,value,,UCH,0=off;1=on,,
[heatpumptype=1]r,,,OverpressureThreshold,Overpressure_Threshold_AW: limit for high pressure when Overpressure should be indicated on A/W machines,,,b509,0dfa00,value,,ULG,,mbar,pressure
[heatpumptype=1]w,,service,OverpressureThreshold,Overpressure_Threshold_AW: limit for high pressure when Overpressure should be indicated on A/W machines,,,b509,0efa00,value,,ULG,,mbar,pressure
[heatpumptype=1]r,,,StartDeicing,Start_Deicing: initiates/indicates a manual deicing process,,,b509,0d7100,value,,UCH,0=no;1=yes,,
[heatpumptype=1]w,,install,StartDeicing,Start_Deicing: initiates/indicates a manual deicing process,,,b509,0e7100,value,,UCH,0=no;1=yes,,
[heatpumptype=1]r,,,TimeBeforeNextDeicing,Time_Before_Next_Deicing: Time until next deicing in 0.5 secs,,,b509,0d7000,value,,ULG,2,s,seconds
[heatpumptype=1]r,,,SourceTempOutputOffset,AirOutlet: Offset for air outlet temperature sensor,,,b509,0dc900,value,,D2C,,K,
[heatpumptype=1]w,,install,SourceTempOutputOffset,AirOutlet: Offset for air outlet temperature sensor,,,b509,0ec900,value,,D2C,,K,
[heatpumptype=5]r,,,SourceTempOutput,BrineOutlet: heat source outlet temperature for brine to water machines,,,b509,0d0800,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=5]u,,,SourceTempOutput,BrineOutlet: heat source outlet temperature for brine to water machines,,,b509,290800,value,,IGN:2,,,,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=5]r,,,SourcePress,P_Brine: Brine pressure sensor,,,b509,0d1600,press,,FLT,,bar,pressure,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=5]r,,,Source,HeatSourcePump BW: Brine Pump BW,,,b509,0d1900,value,,UCH,0=off;1=on,,
[heatpumptype=5]u,,,Source,HeatSourcePump BW: Brine Pump BW,,,b509,291900,value,,IGN:2,,,,value,,UCH,0=off;1=on,,
[heatpumptype=5]r,,,SourceSwitch,BrineSwitch: brine pressure switch; 1 = switch has tripped,,,b509,0d2600,value,,UCH,0=ok;1=error,,
[heatpumptype=5]u,,,SourceSwitch,BrineSwitch: brine pressure switch; 1 = switch has tripped,,,b509,292600,value,,IGN:2,,,,value,,UCH,0=ok;1=error,,
[heatpumptype=5]r,,,CondensorTemp,T_Condensor_BW: Condensor temperature sensor BW,,,b509,0d0d00,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=5]u,,,CondensorTemp,T_Condensor_BW: Condensor temperature sensor BW,,,b509,290d00,value,,IGN:2,,,,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
[heatpumptype=5]r,,,OverpressureThreshold,Overpressure_BW: limit for compressor high pressure which is considered an overpressure situation (for Brine/Water machines),,,b509,0d7701,value,,ULG,,mbar,pressure
[heatpumptype=5]w,,service,OverpressureThreshold,Overpressure_BW: limit for compressor high pressure which is considered an overpressure situation (for Brine/Water machines),,,b509,0e7701,value,,ULG,,mbar,pressure
[heatpumptype=5]r,,,DeltaTempT6T7,Delta_T6_T7_BW: Maximum temperature difference between heat source outlet and inlet - BW,,,b509,0d6e00,value,,D2C,,°C,temperature
[heatpumptype=5]w,,install,DeltaTempT6T7,Delta_T6_T7_BW: Maximum temperature difference between heat source outlet and inlet - BW,,,b509,0e6e00,value,,D2C,,°C,temperature
[heatpumptype=5]r,,,SourcePumpPrerunTime,HS_Pump_Prerun_BW: Heat source pump prerun in heat source circuit - BW,,,b509,0d7600,value,,ULG,120,min,minutes
[heatpumptype=5]w,,install,SourcePumpPrerunTime,HS_Pump_Prerun_BW: Heat source pump prerun in heat source circuit - BW,,,b509,0e7600,value,,ULG,120,min,minutes
[heatpumptype=5]r,,,Bleeding,Initiates and indicates the bleeding function,,,b509,0d1300,value,,UCH,0=no;1=yes,,
[heatpumptype=5]w,,install,Bleeding,Initiates and indicates the bleeding function,,,b509,0e1300,value,,UCH,0=no;1=yes,,
[heatpumptype=5]u,,,Bleeding,Initiates and indicates the bleeding function,,,b509,291300,value,,IGN:2,,,,value,,UCH,0=no;1=yes,,
[heatpumptype=5]r,,,StartDeicing,Start Defrosting,,,b509,0d7100,value,,UCH,0=no;1=yes,,
[heatpumptype=5]w,,install,StartDeicing,Start Defrosting,,,b509,0e7100,value,,UCH,0=no;1=yes,,
[heatpumptype=5]r,,,SourceTempOutputOffset,BrineOutlet: Offset for heat source outlet temperature sensor - BW,,,b509,0dc900,value,,D2C,,K,
[heatpumptype=5]w,,install,SourceTempOutputOffset,BrineOutlet: Offset for heat source outlet temperature sensor - BW,,,b509,0ec900,value,,D2C,,K,
[id_sw=350-400]r,,,CompRestartTimer,"CompressorRestartTimer: Delay until next compressor start, only updated and displayed in UI if compressor demanded but locked by runtime conditions.",,,b509,0d9c01,value,,ULG,120,min,minutes
[id_sw>=403]r,,,CompRestartTimer,"CompressorRestartTimer: Delay until next compressor start, only updated and displayed in UI if compressor demanded but locked by runtime conditions.",,,b509,0dc501,value,,ULG,120,min,minutes
[id_sw>=414]r,,,HysteresisTimeDelay,hysteresis_time_delay: defined time delay until backup heater hysteresis becomes valid,,,b509,0de001,value,,UCH,,min,minutes
[id_sw>=414]w,,install,HysteresisTimeDelay,hysteresis_time_delay: defined time delay until backup heater hysteresis becomes valid,,,b509,0ee001,value,,UCH,,min,minutes
[id_sw>=414]r,,,ActualEnvironmentPowerFine,ActualEnvironmentPowerFine,,,b509,0de201,value,,UCH,,hW,environment power in higher resolution (100W)
[id_sw>=414]u,,,ActualEnvironmentPowerFine,ActualEnvironmentPowerFine,,,b509,29e201,value,,IGN:2,,,,value,,UCH,,hW,environment power in higher resolution (100W)
[id_sw>=414]r,,,BivalentMode,BivalentMode: reserved for special bivalent setting,,,b509,0de301,value,,UCH,,,
[id_sw>=414]w,,install,BivalentMode,BivalentMode: reserved for special bivalent setting,,,b509,0ee301,value,,UCH,,,
[id_sw>=415]r,,,SourceLimitAtMaxFlow,BrineLimitAtMaxFlow: lowest allowed brine temperature to achieve max. flow temperature,,,b509,0de401,value,,SCH,,,
[id_sw>=415]w,,service,SourceLimitAtMaxFlow,BrineLimitAtMaxFlow: lowest allowed brine temperature to achieve max. flow temperature,,,b509,0ee401,value,,SCH,,,
[id_sw>=415]r,,,HysteresisTimerCountdown,HysteresisTimerCountdown: backup heater countdown timer,,,b509,0de701,value,,UCH,,,
[id_sw>=415]r,,,SourceLimitSlope,BrineLimitSlope: Slope to calculate pressure switchpoint below lowest brine temperature,,,b509,0de501,value,,UCH,,,
[id_sw>=415]w,,service,SourceLimitSlope,BrineLimitSlope: Slope to calculate pressure switchpoint below lowest brine temperature,,,b509,0ee501,value,,UCH,,,
[id_sw>=415]r,,,MaxNDPressure,maxNDPressure: max. allowed low pressure for compressor protection,,,b509,0de901,value,,ULG,,,
[id_sw>=415]w,,service,MaxNDPressure,maxNDPressure: max. allowed low pressure for compressor protection,,,b509,0ee901,value,,ULG,,,
[heatpumptype=5][id_sw>=400]r,,,SourceTempOutputT8Min,Einfrierschutz: Minimum heat source outlet temperature VWLS,,,b509,0db001,value,,SCH,,°C,temperature
[heatpumptype=5][id_sw>=400]w,,install,SourceTempOutputT8Min,Einfrierschutz: Minimum heat source outlet temperature VWLS,,,b509,0eb001,value,,SCH,,°C,temperature
[heatpumptype=1][id_sw=350-400]r,,,FanPrerunTime,AW_Fan_Prerun_Time: Prerun time of the fan in s,,,b509,0d9d01,value,,ULG,2,s,seconds
[heatpumptype=1][id_sw=350-400]w,,install,FanPrerunTime,AW_Fan_Prerun_Time: Prerun time of the fan in s,,,b509,0e9d01,value,,ULG,2,s,seconds
[heatpumptype=1][id_sw=350-400]r,,,Hc1PumpPrerunTime,AW_CH1P_Prerun_Time: Prerun time of the internal heat circuit pump in s. Relative to the fan prerun time.,,,b509,0d9e01,value,,ULG,2,s,seconds
[heatpumptype=1][id_sw=350-400]w,,install,Hc1PumpPrerunTime,AW_CH1P_Prerun_Time: Prerun time of the internal heat circuit pump in s. Relative to the fan prerun time.,,,b509,0e9e01,value,,ULG,2,s,seconds
[heatpumptype=1][id_sw>=403]r,,,FanPrerunTime,AW_Fan_Prerun_Time: Prerun time of the fan in s,,,b509,0dc601,value,,ULG,2,s,seconds
[heatpumptype=1][id_sw>=403]w,,install,FanPrerunTime,AW_Fan_Prerun_Time: Prerun time of the fan in s,,,b509,0ec601,value,,ULG,2,s,seconds
[heatpumptype=1][id_sw>=403]r,,,Hc1PumpPrerunTime,AW_CH1P_Prerun_Time: Prerun time of the internal heat circuit pump in s. Relative to the fan prerun time.,,,b509,0dc701,value,,ULG,2,s,seconds
[heatpumptype=1][id_sw>=403]w,,install,Hc1PumpPrerunTime,AW_CH1P_Prerun_Time: Prerun time of the internal heat circuit pump in s. Relative to the fan prerun time.,,,b509,0ec701,value,,ULG,2,s,seconds
[id_sw>=370]r,,,FirstHcEnergySavingPumpOffTime,FirstCHEnergySavingPumpOffTime: CH pump off time for pump switch off during heating operation with direct heating circuits. Function is off from factory but can be activated in service menus via Code1.,,,b509,0d9901,value,,UCH,,min,minutes
[id_sw>=370]w,,install,FirstHcEnergySavingPumpOffTime,FirstCHEnergySavingPumpOffTime: CH pump off time for pump switch off during heating operation with direct heating circuits. Function is off from factory but can be activated in service menus via Code1.,,,b509,0e9901,value,,UCH,,min,minutes
[heatpumptype=2][id_sw=350-400]r,,,Hc1PumpPrerunTime,BW_WW_CH1P_Prerun_Time: Prerun time of the internal heat circuit pump in s. Relative to the heat source pump prerun time.,,,b509,0d9f01,value,,ULG,2,s,seconds
[heatpumptype=2][id_sw=350-400]w,,install,Hc1PumpPrerunTime,BW_WW_CH1P_Prerun_Time: Prerun time of the internal heat circuit pump in s. Relative to the heat source pump prerun time.,,,b509,0e9f01,value,,ULG,2,s,seconds
[heatpumptype=2][id_sw>=403]r,,,Hc1PumpPrerunTime,BW_WW_CH1P_Prerun_Time: Prerun time of the internal heat circuit pump in s. Relative to the heat source pump prerun time.,,,b509,0dc801,value,,ULG,2,s,seconds
[heatpumptype=2][id_sw>=403]w,,install,Hc1PumpPrerunTime,BW_WW_CH1P_Prerun_Time: Prerun time of the internal heat circuit pump in s. Relative to the heat source pump prerun time.,,,b509,0ec801,value,,ULG,2,s,seconds
[heatpumptype=5][id_sw>=403]r,,,Hc1PumpPrerunTime,BW_WW_CH1P_Prerun_Time: Prerun time of the internal heat circuit pump in s. Relative to the heat source pump prerun time.,,,b509,0dc901,value,,ULG,2,s,seconds
[heatpumptype=5][id_sw>=403]w,,install,Hc1PumpPrerunTime,BW_WW_CH1P_Prerun_Time: Prerun time of the internal heat circuit pump in s. Relative to the heat source pump prerun time.,,,b509,0ec901,value,,ULG,2,s,seconds
[heatpumptype=2][id_sw>=350]r,,,SourcePumpCoolingHours,Brine_P_Cooling_Hours: Brine pump run time during cooling,,,b509,0d7d01,value,,ULG,,h,hours
[id_sw>=407]r,,,SourcePumpStatus,BrinePumpStatus: 0=HEP_ok: 1= HEP_error; >=2=noHEP,,,b509,0db801,value,,UCH,,,
[id_sw>=407]u,,,SourcePumpStatus,BrinePumpStatus: 0=HEP_ok: 1= HEP_error; >=2=noHEP,,,b509,29b801,value,,IGN:2,,,,value,,UCH,,,
[id_sw>=407]r,,,SourcePumpPWM,BrinePumpPWM: actual speed of brine pump (7%=off),,,b509,0dac01,value,,UCH,,%,
[id_sw>=407]r,,,SourcePumpSpeedControlHeating,BrinePumpSpeedControlHeating: brine pump speed setpoint when compressor=on,,,b509,0dae01,value,,UCH,,%,
[id_sw>=407]w,,install,SourcePumpSpeedControlHeating,BrinePumpSpeedControlHeating: brine pump speed setpoint when compressor=on,,,b509,0eae01,value,,UCH,,%,
[id_sw>=407]r,,,SourcePumpSpeedControlDefrost,BrinePumpSpeedControlDefrost: brine pump speed setpoint while defrosting,,,b509,0dcc01,value,,UCH,,%,
[id_sw>=407]w,,install,SourcePumpSpeedControlDefrost,BrinePumpSpeedControlDefrost: brine pump speed setpoint while defrosting,,,b509,0ecc01,value,,UCH,,%,
[heatpumptype=5][id_sw>=407]r,,,DeicingActive,DeicingActive: ODU is in defrosting mode,,,b509,0dce01,value,,UCH,0=no;1=yes,,
[heatpumptype=5][id_sw>=407]r,,,Selftest,"selftest adjustable steps: 0=off; 1=StartSelfTest, 30=bleeding (Entlüftung brine circuit)",,,b509,0dd001,value,,UCH,,,
[heatpumptype=5][id_sw>=407]w,,service,Selftest,"selftest adjustable steps: 0=off; 1=StartSelfTest, 30=bleeding (Entlüftung brine circuit)",,,b509,0ed001,value,,UCH,,,
[heatpumptype=5][id_sw>=407]r,,,BivalentPoint2Temp,BivalentPoint2_Temperature: temperature to force backup heater even if it is disabled,,,b509,0dbc01,value,,D2C,,°C,temperature
[heatpumptype=5][id_sw>=407]w,,install,BivalentPoint2Temp,BivalentPoint2_Temperature: temperature to force backup heater even if it is disabled,,,b509,0ebc01,value,,D2C,,°C,temperature
[heatpumptype=5][id_sw>=407]r,,,NoiseReduction,VWLS_NoiseReduction: noise reduction is activated by time schedule,,,b509,0da901,value,,UCH,0=no;1=yes,,
[heatpumptype=5][id_sw>=407]w,,,NoiseReduction,VWLS_NoiseReduction: noise reduction is activated by time schedule,,,b509,0ea901,value,,UCH,0=no;1=yes,,
[heatpumptype=5][id_sw>=407]r,,,NoiseReductionFactor,NoiseReductionFactor: amount of noise reduction when activated by time schedule,,,b509,0d2401,value,,UCH,,%,
[heatpumptype=5][id_sw>=407]w,,,NoiseReductionFactor,NoiseReductionFactor: amount of noise reduction when activated by time schedule,,,b509,0e2401,value,,UCH,,%,
[heatpumptype=5][id_sw>=407]r,,,FanError,VWLS_FanError: fan error OMU 1,,,b509,0da101,value,,UCH,0=no;1=yes,,
[heatpumptype=5][id_sw>=407]r,,,FanErrorOMU2,VWLS_FanError_OMU2: fan error OMU 2,,,b509,0db601,value,,UCH,0=no;1=yes,,
[heatpumptype=5][id_sw>=407]r,,,STBError,VWLS_STBError: defroster STB error OMU 1,,,b509,0da201,value,,UCH,0=no;1=yes,,
[heatpumptype=5][id_sw>=407]r,,,STBErrorOMU2,VWLS_STBError_OMU2: defroster STB error OMU 2,,,b509,0db701,value,,UCH,0=no;1=yes,,
[heatpumptype=5][id_sw>=407]r,,,BadWeather,VWLS_BadWeather: ambient too cold OMU 1,,,b509,0da401,value,,UCH,0=no;1=yes,,
[heatpumptype=5][id_sw>=407]r,,,BadWeatherOMU2,VWLS_BadWeather_OMU2: ambient too cold OMU 2,,,b509,0db901,value,,UCH,0=no;1=yes,,
[heatpumptype=5][id_sw>=407]u,,,BadWeatherOMU2,VWLS_BadWeather_OMU2: ambient too cold OMU 2,,,b509,29b901,value,,IGN:2,,,,value,,UCH,0=no;1=yes,,
[heatpumptype=5][id_sw>=407]r,,,HotSummer,VWLS_HotSummer: ambient too hot OMU 1,,,b509,0db501,value,,UCH,0=no;1=yes,,
[heatpumptype=5][id_sw>=407]r,,,HotSummerOMU2,VWLS_HotSummer_OMU2: ambient too hot OMU 2,,,b509,0db801,value,,UCH,0=no;1=yes,,
[heatpumptype=5][id_sw>=407]u,,,HotSummerOMU2,VWLS_HotSummer_OMU2: ambient too hot OMU 2,,,b509,29b801,value,,IGN:2,,,,value,,UCH,0=no;1=yes,,
r,,,HeatpumpType,heatpump type,,,b509,0d7601,value,,UCH,1=airtowater;2=brinetowater;3=watertowater;4=indirectwatertowater;5=airtobrinetowater,,heatpump type
r,,,CompStartsHwc,Compressor_Commutations_DHW: Number of commutations of,,,b509,0da800,value,,ULG,,,start count
r,,,CompStartsHc,Compressor_Commutations_CH: Number of commutations of,,,b509,0da900,value,,ULG,,,start count
r,,,SourceStarts,Brine_Fan_Commutations: Number of commutations of,,,b509,0dac00,value,,ULG,,,start count
r,,,Hc1PumpStarts,CH1_P_Commutations: Number of commutations of,,,b509,0dad00,value,,ULG,,,start count
r,,,HwcPumpStarts,DHW_P_Commutations: Number of commutations of,,,b509,0dae00,value,,ULG,,,start count
r,,,BackupStartsHwc,Backup_Commutations_DHW: Number of commutations of,,,b509,0daf00,value,,ULG,,,start count
r,,,BackupStartsHc,Backup_Commutations_CH: Number of commutations of,,,b509,0db000,value,,ULG,,,start count
r,,,HwcHcValveStarts,V_DHW_CH_Commutations: Number of commutations of,,,b509,0db300,value,,ULG,,,start count
r,,,CompCutPressHighCount,Compressor_Cut_HP_No: shows how often the compressor has been stopped by high pressure switch,,,b509,0db400,value,,ULG,,,
r,,,CompCutPressLowCount,Compressor_Cut_LP_No: shows how often the compressor has been stopped by low pressure switch,,,b509,0db500,value,,ULG,,,
r,,,CompCutTempCount,Compressor_Cut_T_No: shows how often the compressor has been stopped due to outlet temperature exceeding,,,b509,0db600,value,,ULG,,,
r,,,YieldTotal,EarnedEnvironmentEnergy: sum of earned environmental energy in kWh,,,b509,0dbc00,value,,ULG,,kWh,
w,,service,YieldTotal,EarnedEnvironmentEnergy: sum of earned environmental energy in kWh,,,b509,0ebc00,value,,ULG,,kWh,
u,,,YieldTotal,EarnedEnvironmentEnergy: sum of earned environmental energy in kWh,,,b509,29bc00,value,,IGN:2,,,,value,,ULG,,kWh,
r,,,SourceTempInput,T_Brine_Warm: Brine inlet temperature sensor,,,b509,0d0f00,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
u,,,SourceTempInput,T_Brine_Warm: Brine inlet temperature sensor,,,b509,290f00,value,,IGN:2,,,,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,CompPressHigh,P_Comp_High: High pressure value - Value of high pressure sensor at compressor outlet,,,b509,0d1400,press,,FLT,,bar,pressure,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
u,,,CompPressHigh,P_Comp_High: High pressure value - Value of high pressure sensor at compressor outlet,,,b509,291400,value,,IGN:2,,,,press,,FLT,,bar,pressure,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,CompPressLow,P_Comp_Low: Low pressure value - Value of low pressure sensor at compressor inlet,,,b509,0d1500,press,,FLT,,bar,pressure,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
u,,,CompPressLow,P_Comp_Low: Low pressure value - Value of low pressure sensor at compressor inlet,,,b509,291500,value,,IGN:2,,,,press,,FLT,,bar,pressure,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,Superheat,superheat of refrigerant circuit,,,b509,0d8d00,value,,D2C,,°C,temperature
r,,,Subcooling,subcooling of refrigerant circuit,,,b509,0d8e00,value,,D2C,,°C,temperature
r,,,Integral,actual energy balancing integral,,,b509,0d8000,value,,SIN,,°min,
r,,,TempInput,T_Inlet: Internal compressor inlet temperature sensor,,,b509,0d0200,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
u,,,TempInput,T_Inlet: Internal compressor inlet temperature sensor,,,b509,290200,value,,IGN:2,,,,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,TempOutput,T_Outlet: Internal compressor outlet temperature sensor,,,b509,0d0400,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
u,,,TempOutput,T_Outlet: Internal compressor outlet temperature sensor,,,b509,290400,value,,IGN:2,,,,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,PressSwitch,P_Switch: Compressor High/Low pressure switch chain; 1 = switch chain has tripped,,,b509,0d2500,value,,UCH,0=ok;1=error,,
u,,,PressSwitch,P_Switch: Compressor High/Low pressure switch chain; 1 = switch chain has tripped,,,b509,292500,value,,IGN:2,,,,value,,UCH,0=ok;1=error,,
r,,,Comp,Compressor,,,b509,0d1d00,value,,UCH,0=off;1=on,,
u,,,Comp,Compressor,,,b509,291d00,value,,IGN:2,,,,value,,UCH,0=off;1=on,,
r,,,Backup,Backup heater output,,,b509,0d5f00,value,,UCH,0=off;1=on,,
u,,,Backup,Backup heater output,,,b509,295f00,value,,IGN:2,,,,value,,UCH,0=off;1=on,,
r,,,HcFlowTemp,T_Flow_CH: Internal Flow temperature sensor,,,b509,0d0900,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,HcReturnTemp,T_Return_CH: Internal return temperature sensor,,,b509,0d0a00,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
u,,,HcReturnTemp,T_Return_CH: Internal return temperature sensor,,,b509,290a00,value,,IGN:2,,,,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,HcPress,P_CH: Heating Circuit Pressure sensor,,,b509,0d1200,press,,FLT,,bar,pressure,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,Hc1Pump,CH1_P: internal CH pump,,,b509,0d1700,value,,UCH,0=off;1=on,,
u,,,Hc1Pump,CH1_P: internal CH pump,,,b509,291700,value,,IGN:2,,,,value,,UCH,0=off;1=on,,
r,,,StorageTempTop,T_HB_Top: Heat Buffer Top external temperature sensor,,,b509,0d0100,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
u,,,StorageTempTop,T_HB_Top: Heat Buffer Top external temperature sensor,,,b509,290100,value,,IGN:2,,,,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,StorageTempBottom,T_HB_Bottom: External Heat buffer bottom temperature sensor,,,b509,0d0700,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
u,,,StorageTempBottom,T_HB_Bottom: External Heat buffer bottom temperature sensor,,,b509,290700,value,,IGN:2,,,,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,FlowTemp,"T_Flow_Mixed: External flow temperature sensor - VF2 (flow into the heating system, radiators or floor heating)",,,b509,0d0300,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
u,,,FlowTemp,"T_Flow_Mixed: External flow temperature sensor - VF2 (flow into the heating system, radiators or floor heating)",,,b509,290300,value,,IGN:2,,,,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,Mixer1DutyCycle,"Mixer1DutyCycle: Opening/Closing status of mixing valve HK2, -100%...+100%",,,b509,0d0e00,value,,SCH,,%,
r,,,Hc2Pump,CH2_P: external CH pump (HK2P),,,b509,0d1800,value,,UCH,0=off;1=on,,
r,,,HwcTemp,T_DHW,,,b509,0d0000,temp,,D2C,,°C,External DHW temperature sensor,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
u,,,HwcTemp,T_DHW,,25,b509,290000,value,,IGN:2,,,,temp,,D2C,,°C,External DHW temperature sensor,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,CirPump,CirculationPump: circulation pump,,,b509,0d0c00,value,,UCH,0=off;1=on,,
u,,,CirPump,CirculationPump: circulation pump,,,b509,290c00,value,,IGN:2,,,,value,,UCH,0=off;1=on,,
r,,,HwcHcValve,V_DHW_CH: UV 1,,,b509,0d1000,value,,UCH,0=off;1=on,,
u,,,HwcHcValve,V_DHW_CH: UV 1,,,b509,291000,value,,IGN:2,,,,value,,UCH,0=off;1=on,,
r,,,HwcSwitch,DHW_Switch: one time circulation switch Main PCB input,,,b509,0d0b00,value,,UCH,0=off;1=on,,
r,,,PowerCut,Power_Cut: indicator that EVU has cut the power (according EWD),,,b509,0d1100,value,,UCH,0=no;1=yes,,
r,,,PhaseStatus,"Phase_Status: 3 flags indicating the statuses of the 3 phases at the 380V input (1= phase is there, 0 = phase is missing)",,,b509,0d8800,phase,,BI0,0=missing;1=present,,phase 1 state,phase_1,,BI1,0=missing;1=present,,phase 2 state,phase_2,,BI2,0=missing;1=present,,phase 3 state
u,,,PhaseStatus,"Phase_Status: 3 flags indicating the statuses of the 3 phases at the 380V input (1= phase is there, 0 = phase is missing)",,,b509,298800,value,,IGN:2,,,,phase,,BI0,0=missing;1=present,,phase 1 state,phase_1,,BI1,0=missing;1=present,,phase 2 state,phase_2,,BI2,0=missing;1=present,,phase 3 state
r,,,PhaseOrder,Phase_Order: shows the order of the 3 phases; 7=OK,,,b509,0d5701,value,,UCH,0=error;7=ok,,phase state
u,,,PhaseOrder,Phase_Order: shows the order of the 3 phases; 7=OK,,,b509,295701,value,,IGN:2,,,,value,,UCH,0=error;7=ok,,phase state
r,,,ICLOut,ICL_Out: inrush current limiter,,,b509,0d3f00,value,,UCH,0=off;1=on,,
u,,,ICLOut,ICL_Out: inrush current limiter,,,b509,293f00,value,,IGN:2,,,,value,,UCH,0=off;1=on,,
r,,,OutsideTemp,T_Outside: External outside temperature sensor,,,b509,0d0600,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,ActualEnvironmentPower,ActualEnvironmentPower: only for graphic display: the environmental power that is actually displayed in kW,,,b509,0dba00,value,,UCH,,kW,
u,,,ActualEnvironmentPower,ActualEnvironmentPower: only for graphic display: the environmental power that is actually displayed in kW,,,b509,29ba00,value,,IGN:2,,,,value,,UCH,,kW,
r,,,ActualEnvironmentPowerPercentage,ActualEnvironmentPowerPercentage: only for graphic display: amount of filling of the big energy arrow,,,b509,0dbb00,value,,UCH,,%,
u,,,ActualEnvironmentPowerPercentage,ActualEnvironmentPowerPercentage: only for graphic display: amount of filling of the big energy arrow,,,b509,29bb00,value,,IGN:2,,,,value,,UCH,,%,
r,,,SourcePort,Fan_Brine_Port: port feedback; only needed by UI in actuator test,,,b509,0d3701,value,,UCH,0=off;1=on,,
r,,,Hc1PumpPort,CH1_P_Port: port feedback; only needed by UI in actuator test,,,b509,0d3801,value,,UCH,0=off;1=on,,
r,,,Injection,Injection,,,b509,0d1f00,value,,UCH,0=off;1=on,,
r,,,Date,Actual Date,,,b509,0d2900,value,,HDA:3,,,date
r,,,CompDemand,Compressor_Demand: shows that regulation wants to start the heat source,,,b509,0d5400,value,,UCH,0=no;1=yes,,
r,,,Weekday,Actual Weekday,,,b509,0d2a00,value,,BDY,,,weekday
r,,,Time,Actual Time,,,b509,0d2800,value,,VTI,,,time
r,,,HeatPumpStatus,Heat_Pump_Status: contains the status of the heatpump shown to the installer. Values do not fit here. Please ask R&D for values.,,,b509,0dd000,value,,UCH,0=off;3=heat;6=standby;7=otshutdown;8=water,,heating state
u,,,HeatPumpStatus,Heat_Pump_Status: contains the status of the heatpump shown to the installer. Values do not fit here. Please ask R&D for values.,,,b509,29d000,value,,IGN:2,,,,value,,UCH,0=off;3=heat;6=standby;7=otshutdown;8=water,,heating state
r,,,BackupType,Ext_Backup: Configuration of backup heater installation location,,,b509,0d9200,value,,UCH,0=not_present;1=externalheat;2=externalwater;3=externalheatandwater;4=internalheatandwater,,
w,,install,BackupType,Ext_Backup: Configuration of backup heater installation location,,,b509,0e9200,value,,UCH,0=not_present;1=externalheat;2=externalwater;3=externalheatandwater;4=internalheatandwater,,
r,,,BivalentTemp,Bivalent_Temperature: outside temperature must be lower than this temperature in order to use backup heater for CH,,,b509,0d6500,value,,D2C,,°C,temperature
w,,install,BivalentTemp,Bivalent_Temperature: outside temperature must be lower than this temperature in order to use backup heater for CH,,,b509,0e6500,value,,D2C,,°C,temperature
r,,,BackupHysteresis,Backup_Hysteresis: difference between actual flow temperature and setpoit at which backup heater should start,,,b509,0d7e00,value,,D2C,,°C,temperature
w,,install,BackupHysteresis,Backup_Hysteresis: difference between actual flow temperature and setpoit at which backup heater should start,,,b509,0e7e00,value,,D2C,,°C,temperature
r,,,BackupIntegral,Integral_Backup_Start: integral at which backup heater should start,,,b509,0d7f00,value,,SIN,,°min,
w,,install,BackupIntegral,Integral_Backup_Start: integral at which backup heater should start,,,b509,0e7f00,value,,SIN,,°min,
r,,,BackupModeHc,"Backup_Heater_Mode_CH: backup heater mode for CH: no backup, comfort or backup only",,,b509,0d6300,value,,UCH,0=no_backup;1=withbackup;2=onlybackup,,
w,,install,BackupModeHc,"Backup_Heater_Mode_CH: backup heater mode for CH: no backup, comfort or backup only",,,b509,0e6300,value,,UCH,0=no_backup;1=withbackup;2=onlybackup,,
r,,,BackupModeHwc,"Backup_Heater_Mode_DHW: backup heater mode for DHW: no backup, comfort or backup only",,,b509,0d6400,value,,UCH,0=no_backup;1=withbackup;2=onlybackup,,
w,,install,BackupModeHwc,"Backup_Heater_Mode_DHW: backup heater mode for DHW: no backup, comfort or backup only",,,b509,0e6400,value,,UCH,0=no_backup;1=withbackup;2=onlybackup,,
r,,,BackupPowerCut,"Backup_Power_Cut: This enables the backup heater to run while power cuts as compressor replacement, only applicable if electrical scheme is two.",,,b509,0d8600,value,,UCH,0=no;1=yes,,
w,,service,BackupPowerCut,"Backup_Power_Cut: This enables the backup heater to run while power cuts as compressor replacement, only applicable if electrical scheme is two.",,,b509,0e8600,value,,UCH,0=no;1=yes,,
r,,,CompHysteresis,Compressor_Hysteresis: difference between actual flow temperature and setpoit at which compressor should start,,,b509,0d7d00,value,,D2C,,°C,temperature
w,,install,CompHysteresis,Compressor_Hysteresis: difference between actual flow temperature and setpoit at which compressor should start,,,b509,0e7d00,value,,D2C,,°C,temperature
r,,,CompIntegral,Integral_Comp_Start: integral at which compressor should start,,,b509,0d7c00,value,,SIN,,°min,
w,,install,CompIntegral,Integral_Comp_Start: integral at which compressor should start,,,b509,0e7c00,value,,SIN,,°min,
r,,,NumberCompStarts,Number_Comp_Starts: maximum number of compressor starts per hour,,,b509,0d7400,value,,UCH,,,
w,,install,NumberCompStarts,Number_Comp_Starts: maximum number of compressor starts per hour,,,b509,0e7400,value,,UCH,,,
r,,,ReturnTempMax,"Max_Return_Temperature: if return temperature is higher than this, compressor stops or might not restart",,,b509,0d7300,value,,D2C,,°C,temperature
w,,install,ReturnTempMax,"Max_Return_Temperature: if return temperature is higher than this, compressor stops or might not restart",,,b509,0e7300,value,,D2C,,°C,temperature
r,,,CompHoursHc,Compressor_Hours_CH: operating hours of compressor for CH mode,,,b509,0d9b00,value,,ULG,,h,hours
r,,,CompHours,Compressor_Hours: operating hours of compressor (overall),,,b509,0d9a00,value,,ULG,,h,hours
r,,,CompHoursHwc,Compressor_Hours_DHW: operating hours of compressor for DHW mode,,,b509,0d9c00,value,,ULG,,h,hours
r,,,CompStarts,Compressor_Commutations: Number of commutations of compressor,,,b509,0daa00,value,,ULG,,,start count
r,,,BackupHours,Backup_Hours: operating hours of Backup Heater,,,b509,0da100,value,,ULG,,h,hours
r,,,BackupHoursHc,Backup_Hours_CH: operating hours of Backup Heater for CH,,,b509,0da200,value,,ULG,,h,hours
r,,,BackupHoursHwc,Backup_Hours_DHW: operating hours of Backup Heater for DHW,,,b509,0da300,value,,ULG,,h,hours
r,,,BackupStarts,Backup_Commutations: Number of commutations of backup heater,,,b509,0db100,value,,ULG,,,start count
r,,,ApplianceCode,Appliance_Code: appliance code,,,b509,0d4301,value,,UCH,,,
w,,install,ApplianceCode,Appliance_Code: appliance code,,,b509,0e4301,value,,UCH,,,
u,,,ApplianceCode,Appliance_Code: appliance code,,,b509,294301,value,,IGN:2,,,,value,,UCH,,,
r,,,ElectricWiringDiagram,Electric_Wiring_Diagram: represents the electrical installation (plan 1...3),,,b509,0d8700,value,,UCH,,,
w,,service,ElectricWiringDiagram,Electric_Wiring_Diagram: represents the electrical installation (plan 1...3),,,b509,0e8700,value,,UCH,,,
u,,,ElectricWiringDiagram,Electric_Wiring_Diagram: represents the electrical installation (plan 1...3),,,b509,298700,value,,IGN:2,,,,value,,UCH,,,
r,,,StateSoftwareCode,State_Software_Code: contains several detail information about the actual status of the heatpump for the developer,,,b509,0dcf00,value,,ULG,,,
u,,,StateSoftwareCode,State_Software_Code: contains several detail information about the actual status of the heatpump for the developer,,,b509,29cf00,value,,IGN:2,,,,value,,ULG,,,
r,,,AccelerationTestMode,Acceleration_Test_Mode: initiates/indicates acceleration of several internal timings,,,b509,0d6600,value,,UCH,0=no;1=yes,,
w,,install,AccelerationTestMode,Acceleration_Test_Mode: initiates/indicates acceleration of several internal timings,,,b509,0e6600,value,,UCH,0=no;1=yes,,
u,,,AccelerationTestMode,Acceleration_Test_Mode: initiates/indicates acceleration of several internal timings,,,b509,296600,value,,IGN:2,,,,value,,UCH,0=no;1=yes,,
r,,,Code1,"Code1: together with code 2, this enables/disables several sw features, in hex format",,,b509,0d9700,value,,PIN,,,
w,,install,Code1,"Code1: together with code 2, this enables/disables several sw features, in hex format",,,b509,0e9700,value,,PIN,,,
r,,,Code2,"Code2: together with code 1, this enables/disables several sw features, in hex format",,,b509,0d9800,value,,PIN,,,
w,,install,Code2,"Code2: together with code 1, this enables/disables several sw features, in hex format",,,b509,0e9800,value,,PIN,,,
r,,,Code1Code2Valid,Code1Code2Valid: changes of Code 1 /2 have to be commited by setting this flag,,,b509,0d2400,value,,UCH,0=no;1=yes,,
w,,install,Code1Code2Valid,Code1Code2Valid: changes of Code 1 /2 have to be commited by setting this flag,,,b509,0e2400,value,,UCH,0=no;1=yes,,
r,,,HydraulicScheme,Hzdraulic plan,,,b509,0d6000,value,,UCH,,,Hydraulic Schematic
w,,control,HydraulicScheme,Hzdraulic plan,,,b509,0e6000,value,,UCH,,,Hydraulic Schematic
r,,,HwcLaggingTime,DhwLaggingTime: Backup heater use for CH,,,b509,0d6100,value,,UCH,,,
r,,,HwcLoadingDelay,DhwLoadingDelay: Backup heater use for DHW,,,b509,0d6200,value,,UCH,,,
r,,,SourceHours,Brine_Fan_Hours: operating hours of Fan_Brine,,,b509,0d9d00,value,,ULG,,h,hours
r,,,Source2PumpHours,Brine2_P_Hours: operating hours of Sk2P,,,b509,0d9e00,value,,ULG,,h,hours
r,,,SoftwareCode,SoftwareCode: 4 Bytes holding several software status info,,,b509,0d1801,value,,UCH,,,
r,,,Hc1PumpHours,CH1_P_Hours: operating hours of CH1P,,,b509,0d9f00,value,,ULG,,h,hours
r,,,Hc2PumpHours,CH2_P_Hours: operating hours of HK2P,,,b509,0da000,value,,ULG,,h,hours
r,,,HcModeDemandHours,CH_Mode_Demand_Hours: total time EHP was in CH mode (energy manager),,,b509,0da400,value,,ULG,,h,hours
r,,,HcModeFulfilledHours,CH_Mode_Fulfilled_Hours: total time EHP was in CH mode AND compr. Or backup heater was running,,,b509,0da500,value,,ULG,,h,hours
r,,,HwcModeDemandHours,DHW_Mode_Demand_Hours: total time EHP was in DHW mode (energy manager),,,b509,0da600,value,,ULG,,h,hours
r,,,HwcModeFulfilledHours,DHW_Mode_Fulfilled_Hours: total time EHP was in DHW mode AND compr. Or backup heater was running,,,b509,0da700,value,,ULG,,h,hours
r,,,CompState,CompressorState: compressor and ICL state machine status number,,,b509,0de400,value,,UCH,,,
r,,,TimeCompOnMin,"MinTimeCompressorOn: minimum time that compressor must run in 0,5s steps",,,b509,0de600,value,,ULG,2,s,seconds
r,,,TimeCompOffMin,"MinTimeCompressorOff: minimum time the compressor must be off before restart in 0,5s steps",,,b509,0de700,value,,ULG,2,s,seconds
r,,,TimeBetweenTwoCompStartsMin,"MinTimeBetweenTwoCompressorStarts: calculated from menu item ""compressor starts per hour"" in 0,5s steps",,,b509,0de800,value,,ULG,2,s,seconds
r,,,CompControlState,CompressorControlState: number of status of compressor control state machine,,,b509,0de900,value,,UCH,,,
r,,,RebootCounter,RebootCounter: number of appliance starts,,,b509,0df500,value,,UIN,,,
r,,,T19MaxToCompOff,T19_Max_To_Compressor_Off: limit on compressor outlet temp that leads to an overpressure situation,,,b509,0d2b01,value,,D2C,,°C,temperature
r,,,EnergyBalancingRelease,read/write register,,,b509,0dd100,value,,UCH,0=off;1=on,,
w,,,EnergyBalancingRelease,read/write register,,,b509,0ed100,value,,UCH,0=off;1=on,,
r,,,TimeOfNextPredictedPowerCut,read only updated register,,,b509,0dd300,value,,VTI,,,time
u,,,TimeOfNextPredictedPowerCut,read only updated register,,,b509,29d300,value,,IGN:2,,,,value,,VTI,,,time
r,,,PowerCutPreloading,default *r for register,,,b509,0df400,value,,UCH,0=off;1=on,,
w,,,PowerCutPreloading,default *whwc,,25,b509,0ef400,value,,UCH,0=off;1=on,,
r,,,HcParallelStorageFillingEnabled,"HcParallelTankFillingEnabled: BMR: indicates that heating circuits can keep running at dhw loading; for heatpumps, this is 1 if there is a heat buffer, 0 otherwise",,,b509,0d5500,value,,UCH,0=no;1=yes,,
r,,,OutsideTempOffset,T_Outside_Offset: Offset for calibrating temperature sensor,,,b509,0dc300,value,,D2C,,K,
w,,install,OutsideTempOffset,T_Outside_Offset: Offset for calibrating temperature sensor,,,b509,0ec300,value,,D2C,,K,
r,,,SourceTempInputOffset,T_Brine_Warm_Offset: Offset for calibrating temperature sensor,,,b509,0dcd00,value,,D2C,,K,
w,,install,SourceTempInputOffset,T_Brine_Warm_Offset: Offset for calibrating temperature sensor,,,b509,0ecd00,value,,D2C,,K,
r,,,HwcTempOffset,T_DHW_Offset: Offset for calibrating temperature sensor,,,b509,0dc400,value,,D2C,,K,
w,,install,HwcTempOffset,T_DHW_Offset: Offset for calibrating temperature sensor,,,b509,0ec400,value,,D2C,,K,
r,,,HcFlowTempOffset,T_Flow_CH_Offset: Offset for calibrating temperature sensor,,,b509,0dca00,value,,D2C,,K,
w,,install,HcFlowTempOffset,T_Flow_CH_Offset: Offset for calibrating temperature sensor,,,b509,0eca00,value,,D2C,,K,
r,,,FlowTempOffset,T_Flow_Mixed_Offset: Offset for calibrating temperature sensor,,,b509,0dc500,value,,D2C,,K,
w,,install,FlowTempOffset,T_Flow_Mixed_Offset: Offset for calibrating temperature sensor,,,b509,0ec500,value,,D2C,,K,
r,,,TempInputOffset,T_Inlet_Offset: Offset for calibrating temperature sensor,,,b509,0dc600,value,,D2C,,K,
w,,install,TempInputOffset,T_Inlet_Offset: Offset for calibrating temperature sensor,,,b509,0ec600,value,,D2C,,K,
r,,,TempOutputOffset,T_Outlet_Offset: Offset for calibrating temperature sensor,,,b509,0dc700,value,,D2C,,K,
w,,install,TempOutputOffset,T_Outlet_Offset: Offset for calibrating temperature sensor,,,b509,0ec700,value,,D2C,,K,
r,,,HcReturnTempOffset,T_Return_CH_Offset: Offset for calibrating temperature sensor,,,b509,0dcb00,value,,D2C,,K,
w,,install,HcReturnTempOffset,T_Return_CH_Offset: Offset for calibrating temperature sensor,,,b509,0ecb00,value,,D2C,,K,
r,,,StorageTempBottomOffset,T_HB_Bottom_Offset: Offset for calibrating temperature sensor,,,b509,0d3401,value,,D2C,,K,
w,,install,StorageTempBottomOffset,T_HB_Bottom_Offset: Offset for calibrating temperature sensor,,,b509,0e3401,value,,D2C,,K,
r,,,StorageTempTopOffset,T_HB_Top_Offset: Offset for calibrating temperature sensor,,,b509,0d3301,value,,D2C,,K,
w,,install,StorageTempTopOffset,T_HB_Top_Offset: Offset for calibrating temperature sensor,,,b509,0e3301,value,,D2C,,K,
w,,install,Iotest,I/O test,,,b506,02,value,,UCH,0=off;1=coolvalve;2=sourcepump;3=hcpump;4=injector;5=caseheater;6=backup;7=hwchcvalve;8=cirpump;9=sc2pump;10=hc2pump;11=hc2mixeropen;12=hc2mixerclose,,
w,,install,Ioteststop,stop I/O test,,,b506,01,
r,,,Currenterror,Current errors,,,b503,0001,error,,UIN,,,error number,error_1,,UIN,,,error number,error_2,,UIN,,,error number,error_3,,UIN,,,error number,error_4,,UIN,,,error number
r,,,Errorhistory,Error_History,,,b503,0101,index,m,UCH,,,,status,,UCH,,,Status,time,,VTM,,,time,date,,HDA:3,,,date,error,,UIN,,,error number
w,,install,Clearerrorhistory,Clear error history,,,b503,0201,cleared,s,UCH,0=no;1=yes,,
r,,,DateTime,date/time,,,b504,00,dcfstate,,UCH,0=nosignal;1=ok;2=sync;3=valid,,DCF receiver state,btime,,BTI,,,time,bdate,,BDA,,,date,temp,,D2B,,°C,temperature
r,,,Status16,outside temperature,,,b504,16,value,,D2C,,°C,temperature
uw,,,SetMode,Operation mode,,,b510,00,hcmode,,UCH,0=auto;1=off;2=heat;2=water,,boiler mode,flowtempdesired,,D1C,,°C,temperature,hwctempdesired,,D1C,,°C,temperature,hwcflowtempdesired,,UCH,,°C,temperature,ign,,IGN:1,,,,disablehc,,BI0,,,,disablehwctapping,,BI1,,,,disablehwcload,,BI2,,,,ign_1,,IGN:1,,,,remotecontrolhcpump,,BI0,,,,releasebackup,,BI1,,,,releasecooling,,BI2,,,
r,,,Status01,Vorlauftemperatur/Rücklauftemperatur/Aussentemperatur/WW Temperatur/Speichertemperatur/Pumpenstatus,,,b511,01,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D2B,,°C,temperature,temp_3,,D1C,,°C,temperature,temp_4,,D1C,,°C,temperature,pumpstate,,UCH,0=off;1=on;2=overrun;4=hwc,,pump state
r,,,Status02,Betriebsart/Maximaltemperatur/ReglerCurrentTEMP/Maximaltemperatur/ReglerCurrentTemp,,,b511,02,hwcmode,,UCH,0=disabled;1=on;2=off;3=auto,,hot water mode,temp,,UCH,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,UCH,,°C,temperature,temp_3,,D1C,,°C,temperature
r,,,Status,Status,,,b511,03,temp,,D2C,,°C,temperature,press,,FLT,,bar,pressure,press_1,,FLT,,bar,pressure,hcmode,,UCH,0=off;3=heat;4=water,,boiler mode,hex,,HEX,,,
uw,,,StatusCirPump,Status circulation pump,,,b512,00,value,,UCH,0=off;100=on,,