Notifications
You must be signed in to change notification settings - Fork 0
/
Copy path15.392.csv
We can make this file beautiful and searchable if this error is corrected: It looks like row 2 should actually have 15 columns, instead of 2 in line 1.
153 lines (153 loc) · 22.5 KB
/
15.392.csv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,unit,comment
*r,
*w,
*[id_sw],scan,,,,SW
[id_sw>=125]r,,,DisplayedHwcStorageTemp,DisplayedDHWTankTemperature: display of the storage's temperature in C4 (also in case of an SP1 error),,,b509,0d9e00,value,,D1C,,°C,temperature
[id_sw>=125]r,,,HwcLoadingInBMUActive,DHWLoadingInBMUActive: indicates that BMU is in DHW preparation,,,b509,0d9d00,value,,UCH,0=no;1=yes,,
[id_sw>=125]r,,,MonitorEEpromInkonsiNumber,MonitorEEpromInkonsiNumber,,,b509,0d9f00,value,,HEX:8,,,identification of the last eight EEPROM inconsistencies
[id_sw<=209]r,,,B51000HcDisableMonitor,B51000CHDisableMonitor: copy of the M12 byte of the B5 10 00 service containing the disable bits,,,b509,0d8e00,value,,UCH,,,
[id_sw>=210]r,,,B51000M7OpModeMonitor,"B51000M7OpModeMonitor: operation mode sent via B5 10 00 (0 = auto, 1 = forced off, 2 = forced CH, 3 = forced DHW)",,,b509,0d6500,value,,UCH,,,
[id_sw>=210]r,,,B51000M10HwcFlowSetMon,B51000M10DHWFlowSetMon: flow setpoint DHW sent via B5 10 00,,,b509,0d6600,value,,UCH,,,
[id_sw>=210]r,,,B51000M12DisableBitsMon,"B51000M12DisableBitsMon: bits 0-7: disable CH/disable DHW tapping/disable DHW tank loading/not used/clear burner blocking DHW/dis, disable bits sent via B5 10 00 (leftmost bit 0, rightmost bit 7)",,,b509,0d6700,value,,UCH,,,
[id_sw>=210]r,,,B51000M14Monitor,"B51000M14Monitor: bits 0-7: remote control CH pump/release backup heater/release cooling/not used/left stop position DHW o, bits sent in M14 of B5 10 00 (leftmost bit 0, rightmost bit 7; relevant is bit 0: remote control of CH pump)",,,b509,0d6800,value,,UCH,,,
[id_sw>=126]r,,,AssertFileName,AssertFileName,,,b509,0da000,value,,STR:10,,,"shows, if assert is enabled, the name of the module where the 'assert fail' occured"
[id_sw>=126]r,,,AssertLineNumber,AssertLineNumber: assert fail occured in this line,,,b509,0da100,value,,UIN,,,
r,,,DisplayedRoomTemp,DisplayedRoomTemp: displayed room temperature,,,b509,0d8000,value,,D2C,,°C,temperature
r,,,RoomTemp,RaumtemperaturIst: raw value current room temperature and sensorstate (without any correction),,,b509,0d0000,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,OutsideTemp,OutsideTempSensor: current outdoor temperature and sensorstate,,,b509,0d6200,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,ActualWeekday,ActualWeekday: current day of week,,,b509,0d5f00,value,,BDY,,,weekday
w,,,ActualWeekday,ActualWeekday: current day of week,,,b509,0e5f00,value,,BDY,,,weekday
r,,,Time,current time,,,b509,0d6000,value,,VTI,,,time
w,,,Time,current time,,,b509,0e6000,value,,VTI,,,time
r,,,Date,current date,,,b509,0d6100,value,,HDA:3,,,date
w,,,Date,current date,,,b509,0e6100,value,,HDA:3,,,date
r,,,StatusDcf,StatusDcf: status of the DCF signal (0x00 = no DCF-Signal detected / no RTC value; 0x01 = DCF-signal detected; 0x02 = DCF-signal is being interpreted; 0x03 = DCF-data valid; 0x04 = RTC-data is valid),,,b509,0d0200,value,,UCH,0=nosignal;1=ok;2=sync;3=valid,,DCF receiver state
r,,,IsInHoliday,Holiday function active: holidays active,,,b509,0d0b00,value,,UCH,0=no;1=yes,,
r,,,Hc1OPMode,HC1_OPMode,,,b509,0d2f00,value,,UCH,0=off;1=manual;2=auto,,operation mode of the heating circuit
w,,,Hc1OPMode,HC1_OPMode,,,b509,0e2f00,value,,UCH,0=off;1=manual;2=auto,,operation mode of the heating circuit
r,,,Hc1NightTemp,HC1_NightSetTemp: lowering temperature setpoint of the heating circuit,,,b509,0d3000,value,,D1C,,°C,temperature
w,,,Hc1NightTemp,HC1_NightSetTemp: lowering temperature setpoint of the heating circuit,,,b509,0e3000,value,,D1C,,°C,temperature
r,,,Hc1ManualOPRoomTempDesired,HC1_ManualOPRoomSetpoint: room setpoint in operation mode manual of the heating circuit,,,b509,0d3200,value,,D1C,,°C,temperature
w,,,Hc1ManualOPRoomTempDesired,HC1_ManualOPRoomSetpoint: room setpoint in operation mode manual of the heating circuit,,,b509,0e3200,value,,D1C,,°C,temperature
r,,,Hc1QuickVetoTemp,HC1_QuickVetoTemp: manual override setpoint of the heating circuit,,,b509,0d3c00,value,,D1C,,°C,temperature
r,,,Hc1QuickVetoActive,HC1_QuickVetoActive: manual override of the heating circuit enabled,,,b509,0d3d00,value,,UCH,0=no;1=yes,,
r,,,NameHc,Circuits_Name_HC,,,b509,0d3f00,value,,STR:10,,,labelling of the heating circuit
w,,,NameHc,Circuits_Name_HC,,,b509,0e3f00,value,,STR:10,,,labelling of the heating circuit
r,,,NameHwc,Circuits_Name_DHW,,,b509,0d3f78,value,,STR:10,,,labelling of the domestic hot water circuit
w,,,NameHwc,Circuits_Name_DHW,,,b509,0e3f78,value,,STR:10,,,labelling of the domestic hot water circuit
r,,,HolidayRoomTemp,"HolidayRoomSetTemp: 4.5=frostprotect, room setpoint during holidays",,,b509,0d4000,value,,D1C,,,
w,,,HolidayRoomTemp,"HolidayRoomSetTemp: 4.5=frostprotect, room setpoint during holidays",,,b509,0e4000,value,,D1C,,,
r,,,HolidayStartPeriod,HolidayStartPeriod: start date of holidays,,,b509,0d1100,value,,HDA:3,,,date
w,,,HolidayStartPeriod,HolidayStartPeriod: start date of holidays,,,b509,0e1100,value,,HDA:3,,,date
r,,,HolidayEndPeriod,HolidayEndPeriod: end date of holidays,,,b509,0d1200,value,,HDA:3,,,date
w,,,HolidayEndPeriod,HolidayEndPeriod: end date of holidays,,,b509,0e1200,value,,HDA:3,,,date
r,,,HwcOPMode,DHW_OPMode,,,b509,0d4200,value,,UCH,0=off;1=manual;2=auto,,operation mode of the domestic hot water circuit
w,,,HwcOPMode,DHW_OPMode,,,b509,0e4200,value,,UCH,0=off;1=manual;2=auto,,operation mode of the domestic hot water circuit
r,,,HwcTempDesired,DHW_DesiredTemp: setpoint of domestic hot water circuit,,,b509,0d4400,value,,D1C,,°C,temperature
w,,,HwcTempDesired,DHW_DesiredTemp: setpoint of domestic hot water circuit,,,b509,0e4400,value,,D1C,,°C,temperature
r,,,HwcQuickVetoTemp,DHW_QuickVetoTemp: manual override setpoint for the domestic hot water circuit,,,b509,0d4500,value,,D1C,,°C,temperature
r,,,HwcQuickVetoActive,DHW_QuickVetoActive: manual override of the domestic hot water circuit enabled,,,b509,0d4300,value,,UCH,0=no;1=yes,,
r,,,HwcManualOPTempDesired,DHW_ManualOPSetpoint: setpoint of domestic hot water circuit in manual operation mode,,,b509,0d4c00,value,,D1C,,°C,temperature
w,,,HwcManualOPTempDesired,DHW_ManualOPSetpoint: setpoint of domestic hot water circuit in manual operation mode,,,b509,0e4c00,value,,D1C,,°C,temperature
r,,,SummerWinterTimeAdjust,SummerWinterTimeAdjust: enable automatic switching over to daylight saving's time (when a DCF receiver is connected to the BMU the value is set fix to ON),,,b509,0d5300,value,,UCH,0=off;1=on,,
w,,,SummerWinterTimeAdjust,SummerWinterTimeAdjust: enable automatic switching over to daylight saving's time (when a DCF receiver is connected to the BMU the value is set fix to ON),,,b509,0e5300,value,,UCH,0=off;1=on,,
r,,,DisplayedHc1RoomTempDesired,"DisplayedHK1RoomSetpoint: 0= >5°C, currently displayed room temperature setpoint",,,b509,0d9600,value,,D1C,,°C,temperature
r,,,RoomTempCorrection,RoomTempCorrection: room temperature correction,,,b509,0d5700,value,,SCH,2,K,
w,,install,RoomTempCorrection,RoomTempCorrection: room temperature correction,,,b509,0e5700,value,,SCH,2,K,
r,,,Hc12stepanalogCtrl,HC1_2stepanalogCtrl,,,b509,0d3600,value,,UCH,0=two_point_control;1=analogue_control,,two-point / analogue control
w,,install,Hc12stepanalogCtrl,HC1_2stepanalogCtrl,,,b509,0e3600,value,,UCH,0=two_point_control;1=analogue_control,,two-point / analogue control
r,,,Hc1LineMatchingAdaption,HC1_LineMatchingAdaption: adjustment of closed loop control,,,b509,0d3700,value,,SCH,,,
w,,install,Hc1LineMatchingAdaption,HC1_LineMatchingAdaption: adjustment of closed loop control,,,b509,0e3700,value,,SCH,,,
r,,,Hc1ActualFlowTempDesired,HC1ActualFlowSetPoint: calculated flow temperature setpoint of the heating circuit,,,b509,0d3e00,value,,D1C,,°C,temperature
r,,,HwcLegioStartDay,DHW_LegioStartDay,,,b509,0d4900,value,,UCH,0=Mon;1=Tue;2=Wed;3=Thu;4=Fri;5=Sat;6=Sun;7=off;8=Mon_Sun,,weekday on which legionella protection is started (may also be every day of the week)
w,,install,HwcLegioStartDay,DHW_LegioStartDay,,,b509,0e4900,value,,UCH,0=Mon;1=Tue;2=Wed;3=Thu;4=Fri;5=Sat;6=Sun;7=off;8=Mon_Sun,,weekday on which legionella protection is started (may also be every day of the week)
r,,,HwcLegioStartTime,DHW_LegioStartTime: time on which legionella protection is started,,,b509,0d4a00,value,,VTI,,,time
w,,install,HwcLegioStartTime,DHW_LegioStartTime: time on which legionella protection is started,,,b509,0e4a00,value,,VTI,,,time
r,,,HwcCircuitActive,DHW_CircuitActive: domestic hot water circuit is enabled,,,b509,0d4b00,value,,UCH,0=no;1=yes,,
w,,install,HwcCircuitActive,DHW_CircuitActive: domestic hot water circuit is enabled,,,b509,0e4b00,value,,UCH,0=no;1=yes,,
r,,,PhoneNumber1,aucPhoneNumber_1: first part of the installer's telephone number,,,b509,0d5400,value,,STR:9,,,phone number
w,,install,PhoneNumber1,aucPhoneNumber_1: first part of the installer's telephone number,,,b509,0e5400,value,,STR:9,,,phone number
r,,,PhoneNumber2,aucPhoneNumber_2: second part of the installer's telephone number,,,b509,0d5408,value,,STR:9,,,phone number
w,,install,PhoneNumber2,aucPhoneNumber_2: second part of the installer's telephone number,,,b509,0e5408,value,,STR:9,,,phone number
r,,,KeyCodeforConfigMenu,KeyCodeforConfigMenue,,,b509,0d5500,value,,HEX:4,,,code for the installer's menues
w,,install,KeyCodeforConfigMenu,KeyCodeforConfigMenue,,,b509,0e5500,value,,HEX:4,,,code for the installer's menues
r,,,MaintenanceDate,MaintenanceDate: date of the next maintenance service,,,b509,0d5900,value,,HDA:3,,,date
w,,install,MaintenanceDate,MaintenanceDate: date of the next maintenance service,,,b509,0e5900,value,,HDA:3,,,date
r,,,LcdContrastValue,LcdContrastValue: setting of the LCD contrast,,,b509,0d5a00,value,,UCH,,,
w,,install,LcdContrastValue,LcdContrastValue: setting of the LCD contrast,,,b509,0e5a00,value,,UCH,,,
r,,,CirPump,CircuPumpRunning: circulation pump's state,,,b509,0d8100,value,,UCH,0=off;1=on,,
r,,,HwcActualTempDesired,DHW_ActualDesired_Setpoint: current domestic hot water setpoint,,,b509,0d8600,value,,D1C,,°C,temperature
r,,,StartEepromUpdate,StarteEepromAktualisierung: update of the EEPROM is to be started,,,b509,0d0e00,value,,UCH,0=off;1=on,,
r,,,EepromUpdateActive,EepromAktualisierungAktiv: update of the EEPROM has been started,,,b509,0d0f00,value,,UCH,0=off;1=on,,
r,,,RoomTempOffsetSelfWarming,RaumTempOffsetEigenErwaerm: room temperature intrinsic heating offset,,,b509,0d1500,value,,D2C,,°C,temperature
r,,,CountryVariant,"CountryVariant: country variant (0 = west, 1 = east)",,,b509,0d1700,value,,UCH,,,
r,,,ActualRoomTempDesiredHc1,ActualRoomTempSetpointHC1: current room setpoint considering all basic conditions passed to the control algorithms,,,b509,0d6300,value,,D2C,,°C,temperature
r,,,HRUDetected,HRUDetected: indicates that an airvent module / a heat recovery unit has been detected,,,b509,0d6e00,value,,UCH,0=no;1=yes,,
r,,,ACTOstorDetected,ACTOstorDetected: indicates that an ACTOstor has been detected,,,b509,0d6f00,value,,UCH,0=no;1=yes,,
r,,,BMUB51101ErrorStatus,BMUB51101_ErrorStatus: error state of BMU received via eBUS service B51101,,,b509,0d7000,value,,UCH,,,
r,,,BMUB51101StorageTemp,BMUB51101_TankTemp: hot water storage temperature received via eBUS service B5 11 01,,,b509,0d7100,value,,D1C,,°C,temperature
r,,,LegioProtectActive,LegioProtectActive: legionella protection is active,,,b509,0d7300,value,,UCH,0=no;1=yes,,
r,,,BMUB51101HwcState,BMUB51101_DHWState: flame is on because of either tapping or tank loading,,,b509,0d7500,value,,UCH,0=off;1=on,,
r,,,EnermanState,"EnermanState: current energy-manager-state (Off = 0, Heating = 1, DHW = 2, DHW pump lag = 3)",,,b509,0d7a00,value,,UCH,,,
r,,,CPLPLast24started,CP_LPLast24started: circulation respectively loading pump has been started during the last 24h,,,b509,0d8300,value,,UCH,0=no;1=yes,,
r,,,B51000FlowSetMonitor,B51000FlowSetMonitor: flow temperature setpoint sent via B5 10 00 to the BMU,,,b509,0d8d00,value,,D1C,,°C,temperature
r,,,ChimneySweepModeActive,ChimneySweepModeActive: chimney sweep mode has been enabled by the BMU,,,b509,0d9000,value,,UCH,0=no;1=yes,,
r,,,CcTimer_Monday,Periods Monday,,,b515,0002,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Monday,Periods Monday,,,b515,0002,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Tuesday,Periods Tuesday,,,b515,0102,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Tuesday,Periods Tuesday,,,b515,0102,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Wednesday,Periods Wednesday,,,b515,0202,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Wednesday,Periods Wednesday,,,b515,0202,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Thursday,Periods Thursday,,,b515,0302,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Thursday,Periods Thursday,,,b515,0302,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Friday,Periods Friday,,,b515,0402,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Friday,Periods Friday,,,b515,0402,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Saturday,Periods Saturday,,,b515,0502,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Saturday,Periods Saturday,,,b515,0502,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Sunday,Periods Sunday,,,b515,0602,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Sunday,Periods Sunday,,,b515,0602,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Monday,Periods Monday,,,b515,0001,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Monday,Periods Monday,,,b515,0001,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Tuesday,Periods Tuesday,,,b515,0101,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Tuesday,Periods Tuesday,,,b515,0101,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Wednesday,Periods Wednesday,,,b515,0201,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Wednesday,Periods Wednesday,,,b515,0201,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Thursday,Periods Thursday,,,b515,0301,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Thursday,Periods Thursday,,,b515,0301,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Friday,Periods Friday,,,b515,0401,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Friday,Periods Friday,,,b515,0401,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Saturday,Periods Saturday,,,b515,0501,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Saturday,Periods Saturday,,,b515,0501,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Sunday,Periods Sunday,,,b515,0601,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Sunday,Periods Sunday,,,b515,0601,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,Currenterror,Current errors,,,b503,0001,error,,UIN,,,error number,error_1,,UIN,,,error number,error_2,,UIN,,,error number,error_3,,UIN,,,error number,error_4,,UIN,,,error number
r,,,Errorhistory,Error_History,,,b503,0101,index,m,UCH,,,,status,,UCH,,,Status,time,,VTM,,,time,date,,HDA:3,,,date,error,,UIN,,,error number
w,,install,Clearerrorhistory,Clear error history,,,b503,0201,cleared,s,UCH,0=no;1=yes,,
r,,,HcTimer_Monday,Periods Monday,,,b515,0000,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Monday,Periods Monday,,,b515,0000,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Tuesday,Periods Tuesday,,,b515,0100,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Tuesday,Periods Tuesday,,,b515,0100,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Wednesday,Periods Wednesday,,,b515,0200,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Wednesday,Periods Wednesday,,,b515,0200,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Thursday,Periods Thursday,,,b515,0300,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Thursday,Periods Thursday,,,b515,0300,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Friday,Periods Friday,,,b515,0400,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Friday,Periods Friday,,,b515,0400,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Saturday,Periods Saturday,,,b515,0500,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Saturday,Periods Saturday,,,b515,0500,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Sunday,Periods Sunday,,,b515,0600,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Sunday,Periods Sunday,,,b515,0600,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,Setpoints_Monday,Temperatures Monday,,,b504,1901,value,,IGN:1,,,,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
w,,,Setpoints_Monday,Temperatures Monday,,,b505,2e01,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
r,,,Setpoints_Tuesday,Temperatures Tuesday,,,b504,1902,value,,IGN:1,,,,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
w,,,Setpoints_Tuesday,Temperatures Tuesday,,,b505,2e02,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
r,,,Setpoints_Wednesday,Temperatures Wednesday,,,b504,1903,value,,IGN:1,,,,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
w,,,Setpoints_Wednesday,Temperatures Wednesday,,,b505,2e03,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
r,,,Setpoints_Thursday,Temperatures Thursday,,,b504,1904,value,,IGN:1,,,,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
w,,,Setpoints_Thursday,Temperatures Thursday,,,b505,2e04,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
r,,,Setpoints_Friday,Temperatures Friday,,,b504,1905,value,,IGN:1,,,,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
w,,,Setpoints_Friday,Temperatures Friday,,,b505,2e05,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
r,,,Setpoints_Saturday,Temperatures Saturday,,,b504,1906,value,,IGN:1,,,,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
w,,,Setpoints_Saturday,Temperatures Saturday,,,b505,2e06,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
r,,,Setpoints_Sunday,Temperatures Sunday,,,b504,1907,value,,IGN:1,,,,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
w,,,Setpoints_Sunday,Temperatures Sunday,,,b505,2e07,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature