BeckhoffS7Client

Build status Codacy Badge Licence GitHub All Releases

Unofficial TwinCAT function for S7 Communication

This software is an (unofficial) opensource implementation of TF6610 | TC3 S5/S7 Communication similar to my other project BeckhoffHttpClient.

Main features

Your surely gonna love this software, but if you still need a couple of information for starring this project...

  • FREE! (for commercial use as well)
  • Resilient: doesn't matter what you do with the beckhoff (Start, Stop, Config-Mode, Run-Mode, etc.)
  • Modern: build with the newest TwinCAT Version and .Net Core 3.1
  • Clever: don't need to specify any datatype or bit numbering

Requirements

  • TwinCAT 3.1.4024.7+

How to use this software

Install and setup connections

  • Download the setup and install it on your beckhoff.
  • Ajdust the settings file TFU002.settings.json located C:\TwinCAT\Functions\Unofficial\BeckhoffS7Client putting your connection parameters for all your S7 PLC in the settings file.
{
  "BeckhoffSettings": {
    "AmsNetId": "",
    "Port": 851
  },
  "ExtenalPlcSettings": [
    {
      "Name": "s7-300",
      "IpAddress": "10.30.10.50",
      "Port": 102,
      "Rack": 0,
      "Slot": 2
    }
  ]
}

Use The S7 Attribute

Use the S7 attribute in your project for connect your primitive variables (like an input or output) to a S7.

VAR_GLOBAL
	
	{attribute 'S7.Out'}
	{attribute 'S7.Address' := 'db2.dbx0.0'}
	imAlive : BOOL;

	{attribute 'S7.In'}
	{attribute 'S7.Address' := 'db2.dbx1.0'}
	{attribute 'S7.Plc' := 's7-300'} // you have to select a plc by name only if you have more then one
	otherSystemAlive :BOOL;
	
END_VAR

Supported TwinCAT Datatypes

  • BOOL
  • BYTE und BYTE[]
  • INT / UINT
  • DINT / UDINT
  • LINT / ULINT
  • REAL

S7 Addressing rules

every address has the form (case unsenible) DB<number>.<TYPE><Start>.<Length/Position> i.e.: DB42.DBX0.7 => (means) Datablock 42, Bit (DBX), Start: 0, Position: 7 .

Following types are supported:

  • DBX => Bit (BOOL)
  • DBB => BYTE or BYTE[]
  • INT
  • DINT
  • DUL => LINT
  • D => REAL

Logfiles

Logfiles are saved into C:\TwinCAT\Functions\Unofficial\BeckhoffS7Client\Service.log. You can use TailBlazer for a live view.

Would you like to contribute?

Yes, please!

Try the library and feel free to open an issue or ask for support.

Don't forget to star this project!