On page 28, XECY is wrongly labeled "DFF2". It should be a "DTFF" that has a reset input.
Its data input should be D7 and its reset input should be !RESET7.
This is nitpicky though, since the outputs of XUVA are not connected anyway.
The text was updated successfully, but these errors were encountered:
On page 28,
XECY
is wrongly labeled "DFF2". It should be a "DTFF" that has a reset input.Its data input should be
D7
and its reset input should be!RESET7
.This is nitpicky though, since the outputs of
XUVA
are not connected anyway.The text was updated successfully, but these errors were encountered: