Q47779: Linking without /NOI Causes SYS2070 in Program Calling CRTLIB
/kb/047/Q47779/

Q47779: Linking without /NOI Causes SYS2070 in Program Calling CRTLIB

{% raw %}

Article: Q47779
Product(s): See article
Version(s): 5.10
Operating System(s): OS/2
Keyword(s): ENDUSER | SR# G890807-24188 | mspl13_c
Last Modified: 16-JAN-1990

Programs that are linked with the C run-time library DLL (CRTDLL),
without the /NOI switch, fail with the following message:

   SYS2070:  The system could not demand load the application's
   segment.  CRTLIB __STDOUT is in error.

To avoid the problem, use the /NOI switch when linking. The proper use
of /NOI is described in Section 5.2 of the MTDYNA.DOC file supplied
with Microsoft C Version 5.10.