Article: Q180137
Product(s): Microsoft SNA Server
Version(s): WINDOWS:3.0,3.0 SP1,3.0 SP2,4.0
Operating System(s):
Keyword(s):
Last Modified: 14-MAR-2000
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft SNA Server, versions 3.0, 3.0 SP1, 3.0 SP2, 4.0
-------------------------------------------------------------------------------
SYMPTOMS
========
When using the SnaNls API to convert data to/from Simplified Chinese, incorrect
character conversion may occur.
CAUSE
=====
The following mapping combinations are duplicated in the Snadbcs.tbl file for
Simplified Chinese, which causes conversion problems for the following
characters:
ANSI EBCDIC
A1E4 <-> 4450
A3BF <-> 4345
A3BF <-> 435B
A3BF <-> 445C
A new conversion table was created for SNA Server, and the duplicate mapping
combinations listed above were removed. The following file was changed to
correct this problem:
<snaroot>\system\snadbcs.tbl
for Windows NT, Windows 95 and Windows 3.x clients.
STATUS
======
Microsoft has confirmed this to be a problem in the Microsoft products listed at
the beginning of this article.
This problem was corrected in the latest SNA Server version 3.0 and 4.0 U.S.
Service Packs. For information on obtaining these Service Packs, query on the
following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K