Article: Q258981
Product(s): Microsoft SNA Server
Version(s): 4.0
Operating System(s):
Keyword(s):
Last Modified: 10-NOV-2000
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft SNA Server, version 4.0
-------------------------------------------------------------------------------
SYMPTOMS
========
When you add a logical unit (LU) by using the Snacfg.exe file with a command
file that does not end with a carriage return and line feed pair (CR/LF), you
may receive the following error message:
There is already an LU with this LU Number.
WORKAROUND
==========
You can work around this problem by ensuring that the command file ends in a
carriage return and line feed pair.
MORE INFORMATION
================
Steps to Reproduce the Problem
------------------------------
1. Create a file that is named Job4.txt, and use the following 20 lines as the
text in the file:
LUA PALURD03 /ADD /CONNECTION:APUPOSC1 /POOL:ALURD03 /LUNUMBER:2
LUA PALURD04 /ADD /CONNECTION:APUPOSC1 /POOL:ALURD03 /LUNUMBER:3
LUA PALURD05 /ADD /CONNECTION:APUPOSC1 /POOL:ALURD03 /LUNUMBER:4
LUA PALURD06 /ADD /CONNECTION:APUPOSC1 /POOL:ALURD03 /LUNUMBER:5
LUA PALURE03 /ADD /CONNECTION:APUPOSC1 /POOL:ALURD03 /LUNUMBER:6
LUA PALURE04 /ADD /CONNECTION:APUPOSC1 /POOL:ALURD03 /LUNUMBER:7
LUA PALURE05 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:8
LUA PALURE06 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:9
LUA PALURG03 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:10
LUA PALURG04 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:11
LUA PALURG05 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:12
LUA PALURG06 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:13
LUA PALURH03 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:14
LUA PALURH04 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:15
LUA PALURH05 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:16
LUA PALURH06 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:17
LUA PALURI03 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:18
LUA PALURI04 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:19
LUA PALURI05 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:20
LUA PALURI06 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:21
Make sure that the last line does not end with a carriage return and line feed
pair.
2. Create a connection that is named APUPOSC1.
3. Create an LUA pool that is named ALURD03.
4. Save your changes in SNA Server Manager.
5. Type the following at a command prompt:
"snacfg PATH\@job4.txt /v" (without the quotation marks)
Be sure to use the proper path for the command file.
You receive the following error message:
Line no 20: Processing command to add LUA PALURI06
Assigning LU PALURI06 to connection APUPOSC1
There is already an LU with this LU Number.
Command failed