Notifications
You must be signed in to change notification settings - Fork 23
Agnus Internal Timing
Renee Cousins edited this page May 28, 2020
·
3 revisions
There are two critical internal clocks used by Agnus/Alice, PH2 and PH1. These two clocks appear to be used almost exclusively. PH2 goes low approximately 15ns after CCK goes high and returns high approximately 30ns after CCKQ goes high. PH1 is an inverse of PH2 with another 15ns of padding and is a very narrow signal.
____ _______________
|_______________| |_______ CCK (3.58MHz Color Clock)
____________ _______________
|_______________| CCKQ (3.58MHz Color Clock Quadrature)
______________________ ___________
|_________| PH2 (85ns negative pulse)
_____
________________________| |_____________ PH1 (55ns positive pulse)