! Choice file for use in exercising HOT2000
!
! The H2K model file used is a valid model and nothing needs to be
! changed for it to run! Using "NA" on any of the options below
! leaves the model unchanged for that option (with a few exceptions
! that are noted in comments below).
!-----------------------------------------------------------------------
Opt-Ruleset : NA ! NA, NBC9_36_HRV, NBC9_36_noHRV
! HOT2000 code library file to be used - MUST ALWAYS BE SPECIFIED HERE
Opt-DBFiles : H2KCodeLibFile
! Weather location
Opt-Location : NA
Opt-FuelCost : NA
! Set the output results set that is used to extract outputs
! Note: This is also used to set the "mode" used to run the core.
! NA won't change the input mode in the file and uses the general run results section regardless of mode
Opt-ResultHouseCode: General !NA, General, SOC, HOC, HCV, ROC, Reference, UserHouse
! Archetype file:
Opt-Archetype: NA
! ACH substitutions
Opt-ACH : NA !NA, ACH_1_0
Opt-Ceilings : NA !NA, CeilR40, UsrSpecR40
Opt-AtticCeilings : NA !NA, CeilR40, UsrSpecR40
Opt-CathCeilings : NA !NA, CeilR40, UsrSpecR40
Opt-FlatCeilings : NA !NA, CeilR40, UsrSpecR40
! Main wall definitions
Opt-MainWall : NA ! This one, OR
Opt-GenericWall_1Layer_definitions : NA ! this one, but NOT BOTH
! Exposed floor
Opt-ExposedFloor : NA
! Optical and thermal characteristics of casement windows (all)
Opt-CasementWindows : NA
Opt-Skylights : NA !SkylightDef
Opt-DoorWindows : NA !DoorWinDef
Opt-Doors : NA !SolidWood
! Foundation definitions
Opt-H2KFoundation : OBCminR12-Slab0R ! NA, NBC_BCIN_zone4, OBCminR12-Slab0R
Opt-H2KFoundationSlabCrawl : STEP_SLAB_R0_under ! NA, NBC_SCB_zone4, STEP_SLAB_R0_under
! Hot water system. Choices:
Opt-DHWSystem : NA
Opt-DWHRSystem : none
! HVAC system
Opt-HVACSystem : NA
! HRV spec
Opt-HRVspec : NA
Opt-RoofPitch : NA
! External (Opt-StandoffPV) and Internal model (Opt-H2K-PV) PV options.
! Substitute-h2k.rb will select external if both are specified!
Opt-StandoffPV : NoPV !SizedPV|8kW
Opt-H2K-PV : NA ! MonoSi-200m2 !MonoSi-50m2
!---------------------------------------------------------------------------
! The following options don't do anything for HOT2000
!---------------------------------------------------------------------------
! Set the orientation for the model (N,S,E,W, or AVG to run all four directions
! and compute an average result).
! ***NOTE: As of Dec 2015 this attribute only determines numbers of runs (1 or 4)
! for HOT2000 -- it doesn't rotate the model yet.
GOconfig_rotate : S