Notifications
You must be signed in to change notification settings - Fork 5
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
[ISSUE]: Auto Elect ends randomly, doesnt calibrate the console #13
Comments
I once had tis DVD initialization failed issue on one Phat PS2(cannot remember the actual model). It turns out to be the ribbon cable has two pin corroded away. After a trace fix, PMAP works again. |
I have the same "CD TE LOOP GAIN NG: 127" error on a 50004 console, what does that mean? @AKuHAK |
After a ton of research and understanding of what the source code does CD TE LOOP GAIN NG: 127 means the electrical adjustment for cd is out of spec. You may have a blown laser (mine was). Dont adjust any of the laser pots, and do mechanical adjustment first before the electrical one. You will get it as close to the readme value using the mechanical adjustment, when you are doing this you will be using just the spindle motor and dvd-sl and the white clamp from the top. You will adjust the big screw first and get it to the closest you can then the small screw. After that run the elec one with the proper disks, and it should ask for a cd, the dvdsl then dvd dl if done correct |
@AKuHAK the new version gives this error, when trying to do auto adjust |
Provide the log file, please |
@AKuHAK sorry, can't test it now, cause I've already assembled the console back. Maybe it makes sense to allow skipping the errors during calibration? |
@Sylph4 what console model do you test it on? I don't want to disable it completely, only for some models. |
|
@aaronstevenson408 @fengye @Sylph4 finally found the root of the issue with help of l_oliveira, last build should be fine |
Checks
Describe the issue
having trouble, im using PMAP to adjust a ps2 laser and auto elect ,
it says this and then goes back to the menu and then the mech adjustments fail when i attempt
Console model
SCPH-39001
The text was updated successfully, but these errors were encountered: