Notifications
You must be signed in to change notification settings - Fork 26
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
SmartEVSE drawing more current then specified mains #224
Comments
Could you please post: ...so I can look into this? |
Sorry guys, but you can keep uploading screenshots all you want, as long as nobody uploads a verbose telnet log there is nothing I can do for you.... |
Sorry didn’t know. Will do this afternoon. No problem |
In the mean time, you could test this version: ...which has telnet enabled and limits the charging current ALSO on phases you are not charging on.... Again, totally in the blind here..... |
And just for some extra information. This morning I put the cooker on and saw the car get less power at phase3. And even stopped charging after i turned the oven on. But at the example I uploaded the screenshots of the max current of 20a was not limited. Do I need the latest version you posted to make a Telnet verbose log or can I use v1.8. Regards Paul |
I have it planned, but it's a bit chaotic at work at the moment. Maybe during Christmas. As developer I completely understand you're in the dark. But @paulw5 doesn't have this enabled if I look at his screen shots. Happy holidays to you all. |
@paulw5 Please use the one posted here. |
20231224putty.log And no rush it's just a hobby |
First of all you have "Modem" set to Experiment, it would surprise me if you have a modem attached. Second, if I understand you correctly, this version gives you no problem. Why would you send me a log of a non-erroneous situation? |
GoodMorning and no haven't got a modem attached so will change the setting. |
Last week I tested a lot and seems like the limit is working. What I remember and never linked it with the issue. I sometimes saw in web interface the statement charging |
I specified 28A as mains max power.
I specified 28A as circuit
And 28A as MAX
I see the total system is using 29.5 on L1.
Why doesn't it throttle down to stay below 28A when using SMART charging?
The text was updated successfully, but these errors were encountered: