Name Type Default                               Description                                                             Validation                               Min Max
API_TIMEOUT number 30000 The number of milliseconds a request can be pending before returning a timeout error for data provider request - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
0 60000
API_VERBOSE boolean false Toggle whether the response from the EA should contain just the results or also include the full response body from the queried API.
BACKGROUND_EXECUTE_MS_HTTP number 1000 Time in milliseconds to sleep between HTTP transports' background execute calls, when there are no requests to send - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
1 10000
BACKGROUND_EXECUTE_MS_SSE number 1000 Time in milliseconds to sleep between SSE transports' background execute calls - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
1 10000
BACKGROUND_EXECUTE_MS_WS number 1000 Time in milliseconds to sleep between WS transports' background execute calls - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
1 10000
BACKGROUND_EXECUTE_TIMEOUT number 90000 The maximum amount of time in milliseconds to wait for a background execute to finish - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
1000 180000
BASE_URL string / Starting path for the EA handler endpoint
CACHE_LOCK_DEFERRAL_MS number 60000 The amount of time (in ms) to wait before attempting to lock the cache
CACHE_LOCK_DURATION number 10000 Time (in ms) used as a baseline for the acquisition and extension of cache locks
CACHE_LOCK_RETRIES number 10 Number of retries to acquire a cache lock
CACHE_MAX_AGE number 90000 Maximum amount of time (in ms) that a response will stay cached - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
1000 1200000
CACHE_MAX_ITEMS number 10000 The maximum number of items that remain in the cache - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
1000 10000
CACHE_POLLING_MAX_RETRIES number 10 Max amount of times to attempt to find EA response in the cache after the Transport has been set up - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
0 20
CACHE_POLLING_SLEEP_MS number 200 The number of ms to sleep between each retry to fetch the EA response in the cache - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
10 1000
CACHE_PREFIX string Specifies a prefix to use for cache keys
CACHE_REDIS_CONNECTION_TIMEOUT number 15000 Connection timeout for redis client - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
3000 60000
CACHE_REDIS_HOST string 127.0.0.1 Hostname for the Redis instance to be used
CACHE_REDIS_MAX_RECONNECT_COOLDOWN number 3000 Max cooldown (in ms) before attempting redis reconnection - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
3000 10000
CACHE_REDIS_PASSWORD string undefined The password required for redis auth
CACHE_REDIS_PATH string undefined The UNIX socket string of the Redis server
CACHE_REDIS_PORT number 6379 Port for the Redis instance to be used - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
1 65535
CACHE_REDIS_TIMEOUT number 500 Timeout to fail a Redis server request if no response (ms) - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
500 10000
CACHE_REDIS_URL string undefined The URL of the Redis server. Format: [redis[s]:]//[[user][:password@]][host][:port][/db-number]?db=db-number[&password=bar[&option=value]]] - Value must be a valid URL
CACHE_TYPE enum local The type of cache to use throughout the EA
CENSOR_SENSITIVE_LOGS boolean false Controls whether the logging of sensitive information is enabled or disabled
CORRELATION_ID_ENABLED boolean true Flag to enable correlation IDs for sent requests in logging
DEBUG boolean false Toggles debug mode
DEBUG_ENDPOINTS boolean false Whether to enable debug enpoints (/debug/*) for this adapter. Enabling them might consume more resources.
DEFAULT_CACHE_KEY string DEFAULT_CACHE_KEY Default key to be used when one cannot be determined from request parameters
EA_HOST string :: Host this EA will listen for REST requests on (if mode is set to "reader" or "reader-writer") - Value must be a valid IP address
EA_MODE enum reader-writer Port this EA will listen for REST requests on (if mode is set to "reader" or "reader-writer")
EA_PORT number 8080 Port through which the EA will listen for REST requests (if mode is set to "reader" or "reader-writer") - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
1 65535
EXPERIMENTAL_METRICS_ENABLED boolean true Flag to specify whether or not to collect metrics. Used as fallback for METRICS_ENABLED
LOG_LEVEL string info Minimum level required for logs to be output
MAX_COMMON_KEY_SIZE number 300 Maximum amount of characters that the common part of the cache key or feed ID can have - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
150 500
MAX_HTTP_REQUEST_QUEUE_LENGTH number 200 The maximum amount of queued requests for Http transports before new ones push oldest ones out of the queue - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
1 2000
MAX_PAYLOAD_SIZE_LIMIT number 1048576 Max payload size limit for the Fastify server - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
1048576 1073741824
METRICS_ENABLED boolean true Flag to specify whether or not to startup the metrics server
METRICS_PORT number 9080 Port metrics will be exposed to - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
1 65535
METRICS_USE_BASE_URL boolean undefined Flag to specify whether or not to prepend the BASE_URL to the metrics endpoint
MTLS_ENABLED boolean false Flag to specify whether mutual TLS/SSL is enabled or not
RATE_LIMIT_API_TIER string undefined Rate limiting tier to use from the available options for the adapter. If not present, the adapter will run using the first tier on the list.
RATE_LIMIT_CAPACITY number undefined Used as rate limit capacity per minute and ignores tier settings if defined - Value must be an integer
- Value must be above the minimum
0
RATE_LIMIT_CAPACITY_MINUTE number undefined Used as rate limit capacity per minute and ignores tier settings if defined. Supercedes RATE_LIMIT_CAPACITY if both vars are set - Value must be an integer
- Value must be above the minimum
0
RATE_LIMIT_CAPACITY_SECOND number undefined Used as rate limit capacity per second and ignores tier settings if defined - Value must be an integer
- Value must be above the minimum
0
RATE_LIMITING_STRATEGY enum fixed-interval The rate limiting strategy to use for outbound requests
REQUESTER_SLEEP_BEFORE_REQUEUEING_MS number 0 Time to sleep after a failed HTTP request before re-queueing the request (in ms) - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
0 120000
RETRY number 1 Retry count for failed HTTP requests - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
0 10
SSE_KEEPALIVE_SLEEP number 60000 Maximum amount of time (in ms) between each SSE keepalive request - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
0 120000
SSE_SUBSCRIPTION_TTL number 300000 Maximum amount of time (in ms) an SSE subscription will be cached before being unsubscribed - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
0 3600000
STREAM_HANDLER_RETRY_EXP_FACTOR number 3 The factor for exponential back-off to wait before running the stream handler (1 = no change from STREAM_HANDLER_RETRY_MIN_MS) - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
1 10
STREAM_HANDLER_RETRY_MAX_MS number 1200000 The maximum time (ms) to wait before running the stream handler (takes precedent over STREAM_HANDLER_RETRY_MIN_MS - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
3000 86400000
STREAM_HANDLER_RETRY_MIN_MS number 100 The minimum/base time (ms) to wait before trying to run the stream handler - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
100 10000
SUBSCRIPTION_SET_MAX_ITEMS number 10000 The maximum number of subscriptions set - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
1000 10000
TLS_CA string undefined CA certificate to use for authenticating client certificates
TLS_ENABLED boolean false Flag to specify whether TLS/SSL is enabled or not
TLS_PASSPHRASE string Password to be used to generate an encryption key
TLS_PRIVATE_KEY string undefined Base64 Private Key of TSL/SSL certificate - Value must be a valid base64 string
TLS_PUBLIC_KEY string undefined Base64 Public Key of TSL/SSL certificate - Value must be a valid base64 string
WARMUP_SUBSCRIPTION_TTL number 300000 TTL for batch warmer subscriptions - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
0 3600000
WS_CONNECTION_OPEN_TIMEOUT number 10000 The maximum amount of time in milliseconds to wait for the websocket connection to open (including custom open handler) - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
500 30000
WS_SUBSCRIPTION_TTL number 120000 The time in ms a request will live in the subscription set before becoming stale - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
0 3600000
WS_SUBSCRIPTION_UNRESPONSIVE_TTL number 120000 The maximum acceptable time (in milliseconds) since the last message was received and stored in the cache on a WebSocket connection before it is considered unresponsive, causing the adapter to close and attempt to reopen it. - Value must be an integer
- Value must be above the minimum
- Value must be below the maximum
1000 180000