-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathiot_smart_home.sql
172 lines (158 loc) · 6.94 KB
/
iot_smart_home.sql
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
/*
Navicat Premium Data Transfer
Source Server : localhost
Source Server Type : MySQL
Source Server Version : 80025
Source Host : localhost:3306
Source Schema : iot_smart_home
Target Server Type : MySQL
Target Server Version : 80025
File Encoding : 65001
Date: 13/08/2023 15:11:58
*/
SET NAMES utf8mb4;
SET FOREIGN_KEY_CHECKS = 0;
-- ----------------------------
-- Table structure for iot_app
-- ----------------------------
DROP TABLE IF EXISTS `iot_app`;
CREATE TABLE `iot_app` (
`id` bigint unsigned NOT NULL AUTO_INCREMENT,
`app_id` varchar(32) NOT NULL,
`app_secret` varchar(64) NOT NULL,
`app_type` tinyint unsigned NOT NULL DEFAULT '1' COMMENT '1代表设备,2代表对外开放的app',
PRIMARY KEY (`id`,`app_id`),
UNIQUE KEY `idx_iot_app_app_id` (`app_id`,`app_secret`),
KEY `id` (`id`)
) ENGINE=InnoDB AUTO_INCREMENT=34 DEFAULT CHARSET=utf8mb4 COLLATE=utf8mb4_0900_ai_ci;
-- ----------------------------
-- Table structure for iot_app_proxy
-- ----------------------------
DROP TABLE IF EXISTS `iot_app_proxy`;
CREATE TABLE `iot_app_proxy` (
`id` int NOT NULL AUTO_INCREMENT,
`app_id` varchar(32) CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci DEFAULT '',
`component_app_id` varchar(32) CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci DEFAULT '',
PRIMARY KEY (`id`)
) ENGINE=InnoDB AUTO_INCREMENT=3 DEFAULT CHARSET=utf8mb4 COLLATE=utf8mb4_0900_ai_ci;
-- ----------------------------
-- Table structure for iot_device
-- ----------------------------
DROP TABLE IF EXISTS `iot_device`;
CREATE TABLE `iot_device` (
`id` bigint unsigned NOT NULL AUTO_INCREMENT,
`name` varchar(64) CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci NOT NULL DEFAULT '',
`user_id` bigint unsigned NOT NULL DEFAULT '0',
`app_id` bigint unsigned NOT NULL DEFAULT '0',
`gateway_device_id` int NOT NULL DEFAULT '0',
`device_appid` varchar(64) CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci DEFAULT '',
`type` tinyint unsigned NOT NULL DEFAULT '1',
`type_name` varchar(24) CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci NOT NULL DEFAULT '',
`device_status` tinyint unsigned NOT NULL DEFAULT '1',
`device_cur_status` varchar(500) CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci NOT NULL DEFAULT '',
`online_status` tinyint NOT NULL DEFAULT '0',
`last_ip` varchar(24) CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci NOT NULL DEFAULT '',
`latest_visit` varchar(24) CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci NOT NULL DEFAULT '',
`created_at` datetime NOT NULL DEFAULT CURRENT_TIMESTAMP,
PRIMARY KEY (`id`),
KEY `fk_iot_device_app` (`app_id`),
CONSTRAINT `fk_iot_device_app` FOREIGN KEY (`app_id`) REFERENCES `iot_app` (`id`)
) ENGINE=InnoDB AUTO_INCREMENT=26 DEFAULT CHARSET=utf8mb4 COLLATE=utf8mb4_0900_ai_ci;
-- ----------------------------
-- Table structure for iot_device_operate_log
-- ----------------------------
DROP TABLE IF EXISTS `iot_device_operate_log`;
CREATE TABLE `iot_device_operate_log` (
`id` int NOT NULL AUTO_INCREMENT,
`device_gateway_id` int unsigned DEFAULT '0',
`device_id` int NOT NULL,
`device_type` varchar(24) CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci DEFAULT NULL,
`source` varchar(12) NOT NULL,
`operate_name` varchar(64) NOT NULL,
`operate_number` varchar(64) NOT NULL,
`operate_payload` text CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci NOT NULL,
`operate_level` tinyint NOT NULL DEFAULT '0',
`response_payload` text CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci,
`operate_time` datetime DEFAULT NULL,
`created_at` datetime DEFAULT CURRENT_TIMESTAMP,
`response_ip` varchar(24) DEFAULT NULL,
`response_port` varchar(12) DEFAULT NULL,
`response_time` varchar(24) DEFAULT '',
PRIMARY KEY (`id`)
) ENGINE=InnoDB AUTO_INCREMENT=130 DEFAULT CHARSET=utf8mb4 COLLATE=utf8mb4_0900_ai_ci;
-- ----------------------------
-- Table structure for iot_device_report_log
-- ----------------------------
DROP TABLE IF EXISTS `iot_device_report_log`;
CREATE TABLE `iot_device_report_log` (
`id` int NOT NULL AUTO_INCREMENT,
`device_gateway_id` int unsigned DEFAULT '0',
`device_id` int NOT NULL,
`device_type` varchar(24) CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci DEFAULT NULL,
`source` varchar(12) NOT NULL,
`report_name` varchar(64) NOT NULL,
`report_number` varchar(64) CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci NOT NULL DEFAULT '',
`report_payload` varchar(500) NOT NULL,
`report_level` tinyint NOT NULL DEFAULT '0',
`report_time` datetime DEFAULT NULL,
`report_ip` varchar(24) DEFAULT NULL,
`report_port` varchar(12) DEFAULT NULL,
`created_at` datetime DEFAULT CURRENT_TIMESTAMP,
PRIMARY KEY (`id`)
) ENGINE=InnoDB AUTO_INCREMENT=154 DEFAULT CHARSET=utf8mb4 COLLATE=utf8mb4_0900_ai_ci;
-- ----------------------------
-- Table structure for iot_face_model
-- ----------------------------
DROP TABLE IF EXISTS `iot_face_model`;
CREATE TABLE `iot_face_model` (
`id` int NOT NULL AUTO_INCREMENT,
`user_id` int DEFAULT '0',
`device_appid` varchar(64) NOT NULL,
`user_name` varchar(64) NOT NULL,
`status` tinyint NOT NULL DEFAULT '0',
`urls` text NOT NULL,
`created_at` datetime NOT NULL,
PRIMARY KEY (`id`)
) ENGINE=InnoDB AUTO_INCREMENT=63 DEFAULT CHARSET=utf8mb4 COLLATE=utf8mb4_0900_ai_ci;
-- ----------------------------
-- Table structure for iot_setting
-- ----------------------------
DROP TABLE IF EXISTS `iot_setting`;
CREATE TABLE `iot_setting` (
`key` varchar(120) NOT NULL,
`value` text CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci NOT NULL,
`id` int unsigned NOT NULL AUTO_INCREMENT,
PRIMARY KEY (`id`)
) ENGINE=InnoDB AUTO_INCREMENT=2 DEFAULT CHARSET=utf8mb4 COLLATE=utf8mb4_0900_ai_ci;
-- ----------------------------
-- Table structure for iot_user
-- ----------------------------
DROP TABLE IF EXISTS `iot_user`;
CREATE TABLE `iot_user` (
`id` bigint unsigned NOT NULL AUTO_INCREMENT,
`user_name` varchar(32) CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci NOT NULL,
`mobile` varchar(11) NOT NULL,
`email` varchar(64) CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci NOT NULL,
`password` varchar(64) NOT NULL,
`salt` varchar(12) NOT NULL,
`status` tinyint unsigned NOT NULL DEFAULT '1',
`last_ip` varchar(24) CHARACTER SET utf8mb4 COLLATE utf8mb4_0900_ai_ci DEFAULT '',
`created_at` datetime(3) NOT NULL DEFAULT CURRENT_TIMESTAMP(3),
`register_at` datetime(3) NOT NULL DEFAULT CURRENT_TIMESTAMP(3),
`latest_visit` varchar(24) DEFAULT '',
PRIMARY KEY (`id`),
KEY `index2` (`mobile`)
) ENGINE=InnoDB AUTO_INCREMENT=12 DEFAULT CHARSET=utf8mb4 COLLATE=utf8mb4_0900_ai_ci;
-- ----------------------------
-- Table structure for sessions
-- ----------------------------
DROP TABLE IF EXISTS `sessions`;
CREATE TABLE `sessions` (
`id` varchar(191) NOT NULL,
`data` longtext,
`created_at` datetime(3) DEFAULT NULL,
`updated_at` datetime(3) DEFAULT NULL,
`expires_at` datetime(3) DEFAULT NULL,
PRIMARY KEY (`id`)
) ENGINE=InnoDB DEFAULT CHARSET=utf8mb4 COLLATE=utf8mb4_0900_ai_ci;
SET FOREIGN_KEY_CHECKS = 1;