Error Job IZUD01UZ installing ZOWE PSWI 3.0 #4131

Open
hmerovich56 opened this issue Jan 14, 2025 · 1 comment
Open

Error Job IZUD01UZ installing ZOWE PSWI 3.0 #4131

hmerovich56 opened this issue Jan 14, 2025 · 1 comment
Labels
PSWI z/OSMF PSWI and Workflow question Further information is requested

Comments

@hmerovich56
Copy link

I am trying to install ZOWE PSWi 3.o but when I run the job IZUD01UZ I get

RESTORE INDD(SYSUT1) -
DATASET(INCLUDE( -
ZWE.PSWI.AZWE003.ZFS -
)) -
RENAMEUNCONDITIONAL( -
(ZWE.PSWI.AZWE003.ZFS, -
BTSITE.ZWE.PSWI.AZWE003.ZFS.Ñ) -
) -
NULLSTORCLAS -
NULLMGMTCLAS -
CATALOG -
SHARE CANCELERROR
ADR101I (R/I)-RI01 (01), TASKID 001 HAS BEEN ASSIGNED TO COMMAND 'RESTORE '
ADR109I (R/I)-RI01 (01), 2025.012 22:18:36 INITIAL SCAN OF USER CONTROL STATEMENTS COMPLETED
ADR050I (001)-PRIME(01), DFSMSDSS INVOKED VIA APPLICATION INTERFACE
ADR016I (001)-PRIME(01), RACF LOGGING OPTION IN EFFECT FOR THIS TASK
0ADR006I (001)-STEND(01), 2025.012 22:18:36 EXECUTION BEGINS
0ADR780I (001)-TDDS (01), THE INPUT DUMP DATA SET BEING PROCESSED IS IN LOGICAL DATA SET FORMAT AND WAS CREATED BY
Z/OS DFSMSDSS VERSION 2 RELEASE 5 MODIFICATION LEVEL 0 ON 2024.275 10:40:24
0ADR402E (001)-AUTH (28), AUTHORIZATION CHECK FAILED FOR DATA SET ZWE.PSWI.AZWE003.ZFS, ON VOLUME ZOS003, 4, IN
CATALOG MASTERV.CATALOG
0ADR415W (001)-TDLOG(01), NO DATA SETS WERE COPIED, DUMPED, OR RESTORED FROM ANY VOLUME
0ADR480W (001)-TDLOG(01), THE FOLLOWING DATA SETS WERE NOT PROCESSED FROM THE LOGICALLY FORMATTED DUMP TAPE DUE TO
ERRORS:
0 ZWE.PSWI.AZWE003.ZFS
0ADR006I (001)-STEND(02), 2025.012 22:18:36 EXECUTION ENDS
0ADR013I (001)-CLTSK(01), 2025.012 22:18:36 TASK COMPLETED WITH RETURN CODE 0008
0ADR012I (SCH)-DSSU (01), 2025.012 22:18:36 DFSMSDSS PROCESSING COMPLETE. HIGHEST RETURN CODE IS 0008 FROM:
TASK 001

because I dont have the alias ZWe defined in my system . I want to use BTSITE as my final qualifier.

Can I avoid to define ZWE as an alias on my system?

Best reagrds and thanks in advance

Horacio Merovich

@MarkAckert MarkAckert added PSWI z/OSMF PSWI and Workflow question Further information is requested labels Jan 16, 2025
@muzikovam
Copy link
Contributor

Hi,
unfortunately, this is one of the prerequisities for PSWI deployment and it can't be avoided:

Image