Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Adding IDTs, Cuts, and Waste Storage #449

Open
wants to merge 1 commit into
base: webpack-build
Choose a base branch
from

Conversation

lraiff
Copy link

@lraiff lraiff commented Apr 21, 2022

No description provided.

@netlify
Copy link

netlify bot commented Apr 21, 2022

Deploy Preview for wonderful-blackwell-a043b5 failed.

Name Link
🔨 Latest commit 9a31023
🔍 Latest deploy log https://app.netlify.com/sites/wonderful-blackwell-a043b5/deploys/62616d9b66934c0008e59f3d

@rkrishnasanka
Copy link
Collaborator

@lraiff can you add the corresponding literature citations and design information for this PR ?

@lraiff
Copy link
Author

lraiff commented May 5, 2022

@lraiff can you add the corresponding literature citations and design information for this PR ?

IDT, waste, and cut Citation:
Mazalan, M.B.; Noor, A.M.; Wahab, Y.; Yahud, S.; Zaman, W.S.W.K. Current Development in Interdigital Transducer (IDT) Surface Acoustic Wave Devices for Live Cell In Vitro Studies: A Review. Micromachines 2022, 13, 30. https://doi.org/10.3390/mi13010030
image

I had some trouble getting the part to look exactly like this, so I made several variations of the IDT (ie. Flip, up, down, etc.) so that they could be placed in a similar format as intended. Something was not working with the scaling of the device on my local 3DuF, so I designed the one-sided IDT so that it appeared proportional when designing my device. Our hypothetical design parameters should be: finger width: 75 micrometer and period (perpendicular distance between one finger and another; depends on the needed wavelength but the size is 2mm by 5mm with thickness less than 1 mm). The cut also was not showing up to scale on the device, but I decided to keep this part designed to the correct scale (15 mm x 5 micrometers). I ran out of time to make the second cut exactly but it can easily be made by altering the sliding scales on 3DuF of Cut 1. Cut 2 should be 10mm X 5 micrometers. Both cuts should have a depth of 0.3mm. The paper did not specify the dimensions of the waste, so I made an educated guess. The paper gives information on how the IDT works in a separation process of reagents and the role the Cuts and the waste compartments play in this process.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

Successfully merging this pull request may close these issues.

2 participants