Space IV.5 - Attempt to fix linux unit test failure
Browse files Browse the repository at this point in the history
  • Loading branch information
mjwitte committed Sep 4, 2024
1 parent 6d7509f commit d285a49
Showing 1 changed file with 7 additions and 20 deletions.
27 changes: 7 additions & 20 deletions tst/EnergyPlus/unit/SizingManager.unit.cc
Original file line number Diff line number Diff line change
Expand Up @@ -4166,6 +4166,7 @@ TEST_F(EnergyPlusFixture, SizingManager_ZoneSizing_Coincident_NonAir_10x_Latent_
" Through: 12/31, !- Field 9",
" For: Alldays, !- Field 10",
" Until: 8:00,0.0, !- Field 11",
" Until: 9:00,0.5, !- Field 11",
" Until: 12:00,1.0, !- Field 11",
" Until: 24:00,0.0; !- Field 11",

Expand Down Expand Up @@ -4222,7 +4223,7 @@ TEST_F(EnergyPlusFixture, SizingManager_ZoneSizing_Coincident_NonAir_10x_Latent_
ASSERT_TRUE(process_idf(idf_objects));
SimulationManager::ManageSimulation(*state);

EXPECT_EQ("18987.69", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchSpHtCalcDesLd, "SPACE 1"));
EXPECT_EQ("18989.14", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchSpHtCalcDesLd, "SPACE 1"));
EXPECT_EQ("0.527", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchSpHtCalcDesAirFlow, "SPACE 1"));
EXPECT_EQ("0.527", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchSpHtUserDesAirFlow, "SPACE 1"));
EXPECT_EQ("CHICAGO_IL_USA ANNUAL HEATING 99% DESIGN CONDITIONS DB",
Expand All @@ -4233,7 +4234,7 @@ TEST_F(EnergyPlusFixture, SizingManager_ZoneSizing_Coincident_NonAir_10x_Latent_
EXPECT_EQ("0.669", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchSpClUserDesAirFlow, "SPACE 1"));
EXPECT_EQ("CHICAGO_IL_USA ANNUAL COOLING 1% DESIGN CONDITIONS DB/MCWB",
OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchSpClDesDay, "SPACE 1"));
EXPECT_EQ("7/21 09:00:00", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchSpClPkTime, "SPACE 1"));
EXPECT_EQ("7/21 10:20:00", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchSpClPkTime, "SPACE 1"));

EXPECT_EQ("6311.95", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchSpHtCalcDesLd, "SPACE 2"));
EXPECT_EQ("0.175", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchSpHtCalcDesAirFlow, "SPACE 2"));
Expand Down Expand Up @@ -4262,29 +4263,15 @@ TEST_F(EnergyPlusFixture, SizingManager_ZoneSizing_Coincident_NonAir_10x_Latent_
EXPECT_EQ("7/21 19:00:00", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchSpClPkTime, "SPACE 3"));

// For coincident, expect zone Des Cooling Load to be less than sum of space loads which is 832.44 + 940.2 + 810.65 = 2583.29
EXPECT_EQ("31553.14", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnHtCalcDesLd, "ZONE 1"));
EXPECT_EQ("31554.59", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnHtCalcDesLd, "ZONE 1"));
EXPECT_EQ("0.876", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnHtCalcDesAirFlow, "ZONE 1"));
EXPECT_EQ("0.876", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnHtUserDesAirFlow, "ZONE 1"));
EXPECT_EQ("CHICAGO_IL_USA ANNUAL HEATING 99% DESIGN CONDITIONS DB",
OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnHtDesDay, "ZONE 1"));
EXPECT_EQ("1/21 08:00:00", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnHtPkTime, "ZONE 1"));
EXPECT_EQ("19423.64", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnClCalcDesLd, "ZONE 1"));
EXPECT_EQ("1.348", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnClCalcDesAirFlow, "ZONE 1"));
EXPECT_EQ("1.348", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnClUserDesAirFlow, "ZONE 1"));
EXPECT_EQ("CHICAGO_IL_USA ANNUAL COOLING 1% DESIGN CONDITIONS DB/MCWB",
OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnClDesDay, "ZONE 1"));
EXPECT_EQ("7/21 16:00:00", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnClPkTime, "ZONE 1"));

// For coincident, expect zone Des Cooling Load to be less than sum of space loads which is 832.44 + 940.2 + 810.65 = 2583.29
EXPECT_EQ("31553.14", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnHtCalcDesLd, "ZONE 1"));
EXPECT_EQ("0.876", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnHtCalcDesAirFlow, "ZONE 1"));
EXPECT_EQ("0.876", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnHtUserDesAirFlow, "ZONE 1"));
EXPECT_EQ("CHICAGO_IL_USA ANNUAL HEATING 99% DESIGN CONDITIONS DB",
OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnHtDesDay, "ZONE 1"));
EXPECT_EQ("1/21 08:00:00", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnHtPkTime, "ZONE 1"));
EXPECT_EQ("19423.64", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnClCalcDesLd, "ZONE 1"));
EXPECT_EQ("1.348", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnClCalcDesAirFlow, "ZONE 1"));
EXPECT_EQ("1.348", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnClUserDesAirFlow, "ZONE 1"));
EXPECT_EQ("19406.72", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnClCalcDesLd, "ZONE 1"));
EXPECT_EQ("1.347", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnClCalcDesAirFlow, "ZONE 1"));
EXPECT_EQ("1.347", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnClUserDesAirFlow, "ZONE 1"));
EXPECT_EQ("CHICAGO_IL_USA ANNUAL COOLING 1% DESIGN CONDITIONS DB/MCWB",
OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnClDesDay, "ZONE 1"));
EXPECT_EQ("7/21 16:00:00", OutputReportPredefined::RetrievePreDefTableEntry(*state, state->dataOutRptPredefined->pdchZnClPkTime, "ZONE 1"));
Expand Down

4 comments on commit d285a49

@nrel-bot-2b
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

SpacePart4Followup (mjwitte) - x86_64-Linux-Ubuntu-22.04-gcc-11.4: OK (2900 of 2901 tests passed, 0 test warnings)

Failures:\n

EnergyPlusFixture Test Summary

  • Passed: 1591
  • Failed: 1

Build Badge Test Badge

@nrel-bot
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

SpacePart4Followup (mjwitte) - Win64-Windows-10-VisualStudio-16: OK (2879 of 2879 tests passed, 0 test warnings)

Build Badge Test Badge

@nrel-bot-2b
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

SpacePart4Followup (mjwitte) - x86_64-Linux-Ubuntu-22.04-gcc-11.4-UnitTestsCoverage-RelWithDebInfo: OK (2084 of 2085 tests passed, 0 test warnings)

Failures:\n

EnergyPlusFixture Test Summary

  • Passed: 1591
  • Failed: 1

Build Badge Test Badge Coverage Badge

@nrel-bot-2c
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

SpacePart4Followup (mjwitte) - x86_64-Linux-Ubuntu-22.04-gcc-11.4-IntegrationCoverage-RelWithDebInfo: OK (799 of 799 tests passed, 0 test warnings)

Build Badge Test Badge Coverage Badge

Please sign in to comment.