forked from CVEProject/cvelistV5
-
Notifications
You must be signed in to change notification settings - Fork 0
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
- 1 new CVEs: CVE-2024-51539 - 0 updated CVEs:
- Loading branch information
cvelistV5 Github Action
committed
Feb 25, 2025
1 parent
bd9b4c5
commit 02ccab1
Showing
1 changed file
with
122 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,122 @@ | ||
{ | ||
"dataType": "CVE_RECORD", | ||
"dataVersion": "5.1", | ||
"cveMetadata": { | ||
"cveId": "CVE-2024-51539", | ||
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", | ||
"state": "PUBLISHED", | ||
"assignerShortName": "dell", | ||
"dateReserved": "2024-10-29T05:03:58.393Z", | ||
"datePublished": "2025-02-25T13:45:04.224Z", | ||
"dateUpdated": "2025-02-25T13:45:04.224Z" | ||
}, | ||
"containers": { | ||
"cna": { | ||
"affected": [ | ||
{ | ||
"defaultStatus": "unaffected", | ||
"product": "Secure Connect Gateway - Application", | ||
"vendor": "Dell", | ||
"versions": [ | ||
{ | ||
"lessThan": "5.28.00", | ||
"status": "affected", | ||
"version": "N/A", | ||
"versionType": "semver" | ||
} | ||
] | ||
}, | ||
{ | ||
"defaultStatus": "unaffected", | ||
"product": "Secure Connect Gateway - Appliance", | ||
"vendor": "Dell", | ||
"versions": [ | ||
{ | ||
"lessThan": "5.28.00", | ||
"status": "affected", | ||
"version": "N/A", | ||
"versionType": "semver" | ||
} | ||
] | ||
} | ||
], | ||
"credits": [ | ||
{ | ||
"lang": "en", | ||
"type": "finder", | ||
"value": "CVE-2024-51539: Dell would like to thank saltedfish for reporting this issue." | ||
} | ||
], | ||
"datePublic": "2025-02-24T18:30:00.000Z", | ||
"descriptions": [ | ||
{ | ||
"lang": "en", | ||
"supportingMedia": [ | ||
{ | ||
"base64": false, | ||
"type": "text/html", | ||
"value": "The Dell Secure Connect Gateway (SCG) Application and Appliance, versions prior to 5.28, contains a SQL injection vulnerability due to improper neutralization of special elements used in an SQL command. This vulnerability can only be exploited locally on the affected system. A high-privilege attacker with access to the system could potentially exploit this vulnerability, leading to the disclosure of non-sensitive information that does not include any customer data.<br>" | ||
} | ||
], | ||
"value": "The Dell Secure Connect Gateway (SCG) Application and Appliance, versions prior to 5.28, contains a SQL injection vulnerability due to improper neutralization of special elements used in an SQL command. This vulnerability can only be exploited locally on the affected system. A high-privilege attacker with access to the system could potentially exploit this vulnerability, leading to the disclosure of non-sensitive information that does not include any customer data." | ||
} | ||
], | ||
"metrics": [ | ||
{ | ||
"cvssV3_1": { | ||
"attackComplexity": "LOW", | ||
"attackVector": "LOCAL", | ||
"availabilityImpact": "NONE", | ||
"baseScore": 2.3, | ||
"baseSeverity": "LOW", | ||
"confidentialityImpact": "LOW", | ||
"integrityImpact": "NONE", | ||
"privilegesRequired": "HIGH", | ||
"scope": "UNCHANGED", | ||
"userInteraction": "NONE", | ||
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N", | ||
"version": "3.1" | ||
}, | ||
"format": "CVSS", | ||
"scenarios": [ | ||
{ | ||
"lang": "en", | ||
"value": "GENERAL" | ||
} | ||
] | ||
} | ||
], | ||
"problemTypes": [ | ||
{ | ||
"descriptions": [ | ||
{ | ||
"cweId": "CWE-89", | ||
"description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')", | ||
"lang": "en", | ||
"type": "CWE" | ||
} | ||
] | ||
} | ||
], | ||
"providerMetadata": { | ||
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", | ||
"shortName": "dell", | ||
"dateUpdated": "2025-02-25T13:45:04.224Z" | ||
}, | ||
"references": [ | ||
{ | ||
"tags": [ | ||
"vendor-advisory" | ||
], | ||
"url": "https://www.dell.com/support/kbdoc/en-us/000289550/dsa-2024-464-security-update-for-dell-secure-connect-gateway-application-and-appliance-vulnerability" | ||
} | ||
], | ||
"source": { | ||
"discovery": "UNKNOWN" | ||
}, | ||
"x_generator": { | ||
"engine": "Vulnogram 0.2.0" | ||
} | ||
} | ||
} | ||
} |