Added Sensor Models:
– Teledyne CZMIL
– Teledyne CZMIL Nova
– Teledyne CZMIL Supernova
cBLUE will no longer add subaquous uncertainty to non-subaqueous points’ TPU. Subaqueous processing only generates subaqueous uncertainty for a point if that point has a subaqueous class of 40, 43, 46, or 64.
Subaqueous processing now handles linear or quadratic subaqueous lookup tables.
Subaqueous processing is now versioned at V2.2. The current version of subaqueous processing is stored in the cblue_configuration.json and is included in the output of the metadata JSON file.
Updated user manual to include new sensor models and information on how to read TVU and THU stored in Extra Bytes.