@@ -0,0 +1,180 @@
---
layout: docs
page_title: Migration checklist
description: Use this checklist for decision making related to migrating your Vault deployment to Integrated Storage.
---

# Migration checklist

<Tip title="This is a decision-making checklist">

The purpose of this checklist is not to walk you through the storage
migration steps. This content provides a quick self-check whether it is your
best interest to migrate your Vault storage from an external system to
Integrated Storage.

</Tip>

## Who should use this checklist?

Integrated Storage is a recommended storage option, made available in
Vault 1.4. Vault continues to also support other storage solutions
like Consul.

You should use this checklist if you are operating a Vault deployment backed
by external storage like Consul, and you are considering migration to
Integrated Storage.

## Understand architectural differences

It is important that you understand the differences between operating Vault
with external storage and operating with Integrated Storage. The following
sections detail key differences in architecture between Vault with Consul
storage, and Vault with Integrated Storage to help inform your decision.

### Reference architecture with Consul

The recommended number of Vault instances is **3** in a cluster which connects
to a Consul cluster which may have **5** or more nodes as shown in the diagram.

A total of 8 virtual machines hosts this Vault highly available architecture.

<ImageConfig hideBorder>

![Reference Diagram](/img/diagram-vault-ra-3-az.png)

</ImageConfig>

The processing requirements depend on the encryption and messaging workloads.
Memory requirements are dependant on the total size of secrets stored in
memory. The Vault server itself has minimal storage requirements, but
the Consul nodes should have a high-performance physical storage system.

### Reference architecture with Integrated Storage

The recommended number of Vault instances is **5** in a cluster. In a single HA
cluster, all Vault nodes share the data while an active node holds the lock;
therefore, only the active node has write access. To achieve n-2 redundancy,
(meaning that the cluster can still function after losing 2 nodes),
an ideal size for a Vault HA cluster is 5 nodes.

<Tip title="More deployment details in the documentation">

Refer to the [Integrated
Storage](/vault/docs/internals/integrated-storage#deployment-table)
documentation for more deployment details.

</Tip>

<ImageConfig hideBorder>

![Reference Diagram Details](/img/diagram-vault-integrated-ra-3_az.png)

</ImageConfig>

Because the data gets persisted on the same host, the Vault server should be
hosted on a relatively high-performance hard disk system.

## Consul vs. Integrated Storage

The Integrated Storage eliminates the need for external storage; therefore,
Vault is the only software you need to stand up a cluster. This indicates that
the host machine must have disk capacity in an amount equal or
greater to that of the existing external storage backend.

### System requirements comparison

The fundamental difference between Vault's Integrated Storage and Consul is
that the Integrated Storage stores everything on disk while [Consul
KV](/consul/docs/dynamic-app-config/kv) stores everything in its memory
which impacts the host's RAM.

#### Machine sizes for Vault - Consul as its storage backend

It is recommended to avoid hosting Consul on an instance with burstable CPU.

| Size | CPU | Memory | Disk | Typical Cloud Instance Types |
| ----- | -------- | ------------ | ----- | ----------------------------------------- |
| Small | 2 core | 4-8 GB RAM | 25 GB | **AWS:** m5.large |
| | | | | **Azure:** Standard_D2_v3 |
| | | | | **GCE:** n1-standard-2, n1-standard-4 |
| Large | 4-8 core | 16-32 GB RAM | 50 GB | **AWS:** m5.xlarge, m5.2xlarge |
| | | | | **Azure:** Standard_D4_v3, Standard_D8_v3 |
| | | | | **GCE:** n1-standard-8, n1-standard-16 |

#### Machine sizes for Vault with Integrated Storage

| Size | CPU | Memory | Disk | Typical Cloud Instance Types |
| ----- | -------- | ------------ | ------ | ------------------------------------------ |
| Small | 2 core | 8-16 GB RAM | 100 GB | **AWS:** m5.large, m5.xlarge |
| | | | | **Azure:** Standard_D2_v3, Standard_D4_v3 |
| | | | | **GCE:** n2-standard-2, n2-standard-4 |
| Large | 4-8 core | 32-64 GB RAM | 200 GB | **AWS:** m5.2xlarge, m5.4xlarge |
| | | | | **Azure:** Standard_D8_v3, Standard_D16_v3 |
| | | | | **GCE:** n2-standard-8, n2-standard-16 |

If many secrets are being generated or rotated frequently, this information will
need to be flushed to the disk often. Therefore, the infrastructure should have
a relatively high-performance hard disk system when using the integrated
storage.

<Note title="A note about the importance of IOPS">

Vault's Integrated Storage is disk-bound; therefore, care should be taken when planning storage volume size and performance. For cloud providers, IOPS can be dependent on volume size and/or provisioned IOPS. It is recommended to provision IOPS and avoid burstable IOPS. Monitoring of IOPS performance should be implemented in order to tune the storage volume to the IOPS load.

</Note>

### Performance considerations

Because Consul KV is memory-bound, it is necessary to take a snapshot frequently.
However, Vault's Integrated Storage persists everything on the disk which eliminates
the need for such frequent snapshot operations. Take snapshots to back up the data
so that you can restore them in case of data loss. This reduces the performance cost
introduced by the frequent snapshot operations.

In considering disk performance, since Vault data changes are immediately written to disk,
rather than in batched snapshots as Consul does, it is important to monitor IOPS as well
as disk queues to limit storage bottlenecks.


### Inspect Vault data

Inspection of Vault data differs considerably from the `consul kv` commands used
to inspect Consul's KV store.
Consult the [Inspect Data in Integrated Storage](/vault/tutorials/monitoring/inspect-data-integrated-storage)
tutorial to learn more about querying Integrated Storage data.

### Summary

The table below highlights the differences between Consul and integrated
storage.

| Consideration | Consul as storage backend | Vault Integrated Storage |
| ------------------- | -------------------------------------------------------------------------- | -------------------------------------------------------------------------------------------- |
| System requirement | Memory optimized machine | Storage optimized high IOPS machine |
| Data snapshot | Frequent snapshots | Normal data backup strategy |
| Snapshot automation | Snapshot agent (**Consul Enterprise only**) | Automatic snapshot (**Vault Enterprise v1.6.0 and later**) |
| Data inspection | [Online, use `consul kv` command](/vault/tutorials/monitoring/inspecting-data-consul) | [Offline, requires using recovery mode](/vault/tutorials/monitoring/inspect-data-integrated-storage) |
| Autopilot | Supported | Supported (**Vault 1.7.0 and later**) |

## Self-check questions

- [ ] Where is the product expertise?
- [ ] Do you already have Consul expertise?
- [ ] Are you concerned about lack of Consul knowledge?
- [ ] Do you experience any technical issues with Consul?
- [ ] What motivates the data migration from the current storage to Integrated Storage?
- [ ] Reduce the operational overhead?
- [ ] Reduce the number of machines to run?
- [ ] Reduce the cloud infrastructure cost?
- [ ] Do you have a staging environment where you can run production loads and verify that everything works as you expect?
- [ ] Have you thought through the storage backup process or workflow after migrating to the Integrated Storage?
- [ ] Do you currently rely heavily on using Consul to inspect Vault data?

## Tutorials

If you are ready to migrate the current storage backend to Integrated Storage,
refer to the [Storage Migration Tutorial - Consul to Integrated Storage](/vault/tutorials/raft/raft-migration).

To deploy a new cluster with Integrated Storage, refer to the [Vault HA Cluster
with Integrated Storage](/vault/tutorials/raft/raft-storage) tutorial.
4 changes: 4 additions & 0 deletions website/data/docs-nav-data.json
Original file line number Diff line number Diff line change
Expand Up @@ -251,6 +251,10 @@
{
"title": "Autopilot",
"path": "concepts/integrated-storage/autopilot"
},
{
"title": "Migration checklist",
"path": "concepts/integrated-storage/migration-checklist"
}
]
},
Expand Down
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added website/public/img/diagram-vault-ra-3-az.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.

0 comments on commit d65a5a6

Please sign in to comment.