HPXML 3.1
v3.1 Changelog
- DataTypes cleanup by @shorowit in #265
- Adds wood stud wall framing type field by @shorowit in #261
- Adds storm window material field by @shorowit in #259
- Removes outdated reference to HPXML wiki by @shorowit in #258
- Requires AssemblyEffectiveRValue to be > 0 by @shorowit in #257
- Add CEER to cooling efficiency units by @yzhou601 in #254
- Adds PerformanceClass element for fenestration by @shorowit in #248
- DSE values as fractions by @shorowit in #246
- Radiant Barrier grade by @shorowit in #234
- Adobe wall type by @shorowit in #230
- RimJoist Siding/Color by @shorowit in #227
- PerformanceAdjustment clarification by @shorowit in #226
- Adds VentilationFan/Quantity by @shorowit in #225
- Adds an extension to the WaterHeating element by @shorowit in #224
- Adds Dishwasher/ClothesWasher label fields by @shorowit in #223
- Adds units to CollectorRatedOpticalEfficiency by @shorowit in #220
- Indirect water heater standby loss by @shorowit in #214
- Adds UsageBin element for water heaters by @shorowit in #276
- Adds InteriorFinish element for enclosure surfaces by @shorowit in #274
- Update IECC Year choices by @shorowit in #273
- Add Location for storm windows by @shorowit in #272
- Add Location for more appliances by @shorowit in #271
- Adds "none" as a siding type by @shorowit in #267
- HeatingSeason and CoolingSeason by @joseph-robertson in #262
- Adds clothes dryer venting fields by @shorowit in #255
- Address input vs output heating capacities by @shorowit in #249
- Continuous Integration Testing by @nmerket in #278
- Adds a window type field by @shorowit in #260
- Adds FuelLoads element (similar to PlugLoads) by @joseph-robertson in #228
- WithinInfiltrationVolume element for Attics/Foundations by @shorowit in #216
- Additional Dehumidifier properties by @shorowit in #208
- Renames BaseElements.xsd to HPXMLBaseElements.xsd. by @shorowit in #282
- Infiltration Height by @shorowit in #297
- Add
FoundationWall/Type
enumerations by @shorowit in #293 - AtticType/BelowApartment by @shorowit in #291
- Adds more window property choices by @shorowit in #288
- Compressor type for ACs/HPs by @shorowit in #219
- Number of units by @shorowit in #316
- [technically breaking change] Update
Overhangs
to use units of ft by @shorowit in #312 - Add HeatPump lockout temperature elements by @shorowit in #309
- Relax requirement for
Building/Site/Address
by @shorowit in #302 - MBtu units by @shorowit in #299
- Expand
Building/Site
by @shorowit in #301 - Clarify documentation for thickness elements by @shorowit in #314
- Adds "conditioned space" enumeration by @shorowit in #318
- [technically breaking change] Disallow zero for efficiencies by @shorowit in #319
- Adds SEER2, EER2, and HSPF2 by @shorowit in #326
- Example files and prep for v3.1 by @nmerket in #328
New Contributors
- @yzhou601 made their first contribution in #254
- @joseph-robertson made their first contribution in #262
Full Changelog: v3.0...v3.1