Implement VWZ Live Monitor readings & Test Menu
Signed-off-by: kjoglum <[email protected]>
- Loading branch information
Showing
2 changed files
with
140 additions
and
104 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,52 +1,70 @@ | ||
# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment | ||
*r,,,,,,"B511",,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,State,,,,,07,energy,,UCH,,,,,,energy,,kWh,,onoff,,UCH,0=off;1=on,,,state,,UCH,0x01=ready;0x0b=error;0x09=heating;0x11=cooling;0x81=heating_water,, | ||
# Heatpump statistics,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B51A","05FF32",,,IGN:3,,,,,,,,,,,,,,,,,,,,, | ||
r,,EnergyHc,,,,,00,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
r,,EnergyCool,,,,,01,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
r,,Hours,,,,,40,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
r,,HoursHc,,,,,41,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
r,,HoursCool,,,,,43,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
# some more statistics from Live Monitor,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,CurrentYieldPower,,,,,23,,,D1B,10,kW,aktuell gewonnene Energie aus der Umwelt in kW,,,,,,,,,,,,,,,,,, | ||
r,,CurrentConsumedPower,,,,,24,,,D1B,10,kW,aktueller Stromverbrauch der Wärmepumpe in kW,,,,,,,,,,,,,,,,,, | ||
r,,CurrentCompressorUtil,,,,,25,,,D1B,,%,aktuelle Kompressorauslastung in Prozent,,,,,,,,,,,,,,,,,, | ||
# Total heating yields,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B516","18",,,IGN:1,,,,,,,,,,,,,,,,,,,,, | ||
r,,YieldTotal,,,,,01,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
# Total electric power consumption,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,ConsumptionTotal,,,,,02,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
# Ecologic energy Yields,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B516","1A01",,,IGN:1,,,,,,,,,,,,,,,,,,,,, | ||
r,,YieldThisYear1,,,,,0100,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear2,,,,,0200,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear3,,,,,0300,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear4,,,,,0400,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear5,,,,,0500,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear6,,,,,0600,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear7,,,,,0700,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear8,,,,,0800,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear9,,,,,0900,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear10,,,,,0A00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear11,,,,,0B00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear12,,,,,0C00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
# Electric power consumption,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B516","1A02",,,IGN:1,,,,,,,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear1,,,,,0100,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear2,,,,,0200,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear3,,,,,0300,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear4,,,,,0400,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear5,,,,,0500,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear6,,,,,0600,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear7,,,,,0700,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear8,,,,,0800,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear9,,,,,0900,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear10,,,,,0A00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear11,,,,,0B00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear12,,,,,0C00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
# Values from UniTower Test Menu,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,B514,05,,,IGN:2,,,,,,,,,,,,,,,,,,,,, | ||
r,,WaterThroughput,,,,,2B03FFFF,,,UIN,,l/h,Aktuelle Heizwasser Durchflussrate der Wärmepumpe in Liter pro Stunde,,,,,,,,,,,,,,,,,, | ||
!include,hcmode.inc,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
!include,errors.inc,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment | ||
*r,,,,,,B511,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,State,,,,,07,energy,,UCH,,,,,,energy,,kWh,,onoff,,UCH,0=off;1=on,,,state,,UCH,0x01=ready;0x0b=error;0x09=heating;0x11=cooling;0x81=heating_water,,,,,,,, | ||
# Values from VWZ menu (Live Monitor),,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,B51A,05,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*w,,,,,,B51A,05,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
w,,ReadLiveMonitor,Payload needed sent: 00321f=desired supply (D2C);003220=current supply (D2C);003224=current power consumption (UIN);003223=power generated (UIN);003225=Modulation (D1B);003226=Air intake (D2C),,,,,,m,HEX:3,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,LiveMonitor,,,,,,,m,IGN:2,,,,subid,m,HEX:1,,,,,,IGN:3,,,,value,,HEX:2,,,,,,IGN:5,,, | ||
r,,EnergyHc,,,,,FF3200,,,energy,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,EnergyCool,,,,,FF3201,,,energy,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,Hours,,,,,FF3240,,,energy,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,HoursHc,,,,,FF3241,,,energy,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,HoursCool,,,,,FF3243,,,energy,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,CurrentYieldPower,,,,,FF3223,,,D1B,10,kW,aktuell gewonnene Energie aus der Umwelt in kW,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,CurrentConsumedPower,,,,,FF3224,,,D1B,10,kW,aktueller Stromverbrauch der Wärmepumpe in kW,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,CurrentCompressorUtil,,,,,FF3225,,,D1B,,%,aktuelle Kompressorauslastung in Prozent,,,,,,,,,,,,,,,,,,,,,,,, | ||
# Additional values from VWZ menu (Live Monitor Main),,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,B503,00,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*w,,,,,,B503,00,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
w,,ReadLiveMonitorMain,Payload needed sent: 03FFFF,,,,,,m,HEX:1,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,LiveMonitorMain,,71,,,,id,,UCH,0x39=Controller starting;0xf4=Standby;0xf5=Supply on;0xf6=Heating: Flow ok;0xf7=Heating: temperature self test;0xf8=Heating: Start;0xfa=Heating: Fan on;0xfc=EEV switch;0xfd=Compressor starting;0xfe=Heating: compressor on;0x00=Compressor off;0x02=Compressor coast down;0x03=Deicing start;0x04=Deicing;0x05=Deicing end;0x12=Cooling: Flow on;0x14=Cooling: temperature self test;0x15=Cooling: starting;0x17=Cooling: Fan on;0x13=Cooling: Flow ok;0x19=Cooling: EEV?;0x1a=Cooling: compressor starting;0x1b=Cooling: compressor on;0x1d=Cooling: ending;0x29=Start condition not met;0x57=Device error;0x44=Flow error in distribution system,,,function,,UCH,0x01=Heating;0x02=Cooling,,,,,,,,,,,,,,,,,,,, | ||
# Values from VWZ test menu & UniTower test menu,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,B514,05,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*w,,,,,,B514,05,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
w,,ReadEEVPosition,Read T.008,,,,15,,m,HEX:3,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,EEVPosition,T.008 value,,,,15,,,IGN:2,,,,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
w,,ReadCompressorExitTemp,Read T.026,,,,37,,m,HEX:3,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,CompressorExitTemp,T.026 value,,,,37,,,IGN:2,,,,,,SIN,10,,,,,,,,,,,,,,,,,,,, | ||
w,,ReadCompressorIntakeTemp,Read T.027,,,,38,,m,HEX:3,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,CompressorIntakeTemp,T.027 value,,,,38,,,IGN:2,,,,,,SIN,10,,,,,,,,,,,,,,,,,,,, | ||
w,,ReadDeliveryFlow,Read T.016,,,,2B,,m,HEX:3,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,DeliveryFlow,T.016 value,,,,2B,,,IGN:2,,,,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
w,,ReadCompressorSpeed,Read T.068,,,,5D,,m,HEX:3,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,CompressorSpeed,T.068 value,,,,5D,,,IGN:2,,,,,,UIN,10,,,,,,,,,,,,,,,,,,,, | ||
r,,WaterThroughput,,,,,2B03FFFF,,,UIN,,l/h,Aktuelle Heizwasser Durchflussrate der Wärmepumpe in Liter pro Stunde,,,,,,,,,,,,,,,,,,,,,,,, | ||
# Total heating yields,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,B516,18,,,IGN:1,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,YieldTotal,,,,,01,,,energy,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
# Total electric power consumption,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,ConsumptionTotal,,,,,02,,,energy,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
# Ecologic energy Yields,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,B516,1A01,,,IGN:1,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,YieldThisYear1,,,,,0100,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,YieldThisYear2,,,,,0200,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,YieldThisYear3,,,,,0300,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,YieldThisYear4,,,,,0400,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,YieldThisYear5,,,,,0500,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,YieldThisYear6,,,,,0600,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,YieldThisYear7,,,,,0700,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,YieldThisYear8,,,,,0800,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,YieldThisYear9,,,,,0900,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,YieldThisYear10,,,,,0A00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,YieldThisYear11,,,,,0B00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,YieldThisYear12,,,,,0C00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
# Electric power consumption,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,B516,1A02,,,IGN:1,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear1,,,,,0100,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear2,,,,,0200,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear3,,,,,0300,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear4,,,,,0400,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear5,,,,,0500,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear6,,,,,0600,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear7,,,,,0700,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear8,,,,,0800,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear9,,,,,0900,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear10,,,,,0A00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear11,,,,,0B00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear12,,,,,0C00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,,,,,,, | ||
!include,hcmode.inc,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
!include,errors.inc,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, |