First attempt at adding docs for new IFM KQ1001 agent.
- Loading branch information
Showing
2 changed files
with
106 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,105 @@ | ||
.. highlight:: rst | ||
|
||
.. _ifm_kq1001_levelsensor: | ||
|
||
========================== | ||
IFM KQ1001 Level Sensor Agent | ||
========================== | ||
|
||
The IFM KQ1001 Level Sensor Agent is an OCS Agent which monitors the | ||
fluid level in percent reported by the sensor. The agent also records | ||
the device status of the KQ1001 sensor. Monitoring is performed by | ||
connecting the level sensor device to an IO-Link master device from | ||
the same company; the querying of level sensor data is done via HTTP | ||
requests to the IO-Link master. | ||
|
||
.. argparse:: | ||
:filename: ../socs/agents/ifm_kq1001_levelsensor/agent.py | ||
:func: add_agent_args | ||
:prog: python3 agent.py | ||
|
||
Configuration File Examples | ||
--------------------------- | ||
|
||
Below are configuration examples for the ocs config file and for running the | ||
Agent in a docker container. | ||
|
||
OCS Site Config | ||
``````````````` | ||
|
||
To configure the IFM KQ1001 Level Sensor Agent we need to add a | ||
LevelSensorAgent block to our ocs configuration file. Here is an | ||
example configuration block using all of the available arguments:: | ||
|
||
{'agent-class': 'LevelSensorAgent', | ||
'instance-id': 'level', | ||
'arguments': [['--ip-address', '10.10.10.159'], | ||
['--daq-port', '2']]}, | ||
|
||
.. note:: | ||
The ``--ip-address`` argument should use the IP address of the IO-Link | ||
master. | ||
|
||
Docker Compose | ||
`````````````` | ||
|
||
The IFM KQ1001 Level Sensor Agent should be configured to run in a | ||
Docker container. An example docker compose service configuration is | ||
shown here:: | ||
|
||
ocs-level: | ||
image: simonsobs/socs:latest | ||
hostname: ocs-docker | ||
network_mode: "host" | ||
volumes: | ||
- ${OCS_CONFIG_DIR}:/config:ro | ||
environment: | ||
- INSTANCE_ID=level | ||
- SITE_HUB=ws://127.0.0.1:8001/ws | ||
- SITE_HTTP=http://127.0.0.1:8001/call | ||
- LOGLEVEL=info | ||
|
||
The ``LOGLEVEL`` environment variable can be used to set the log level for | ||
debugging. The default level is "info". | ||
|
||
Description | ||
----------- | ||
|
||
The KQ1001 Level Sensor is a device from IFM Electronic, and can be | ||
used to monitor the level of a process fluid (like water) in a | ||
nonconductive tank through the tank wall. The sensor can be | ||
noninvasively taped to the outside of the tank. The sensor must be | ||
calibrated to the tank before it can report level readings. The | ||
calibration is best if performed on the tank when it is empty or full, | ||
but can also be performed if the tank is partially full. For more | ||
information on the calibration, see the operating instructions for the | ||
KQ1001, available on the IFM website. The Agent communicates with the | ||
level sensor via an AL1340 IFM Electronic device--an IO-Link master | ||
from which the agent makes HTTP requests. The level sensor plugs into | ||
1 of 4 ports on the IO-Link master, and the agent queries data | ||
directly from that IO-Link master port. This is only possible when an | ||
ethernet connection is established via the IO-Link master's IoT port. | ||
|
||
IO-Link Master Network | ||
``````````````````````` | ||
Once plugged into the IoT port on your IO-Link master, the IP address of the | ||
IO-Link master is automatically set by a DHCP server in the network. If no DHCP | ||
server is reached, the IP address is automatically assigned to the factory setting | ||
for the IoT port (169.254.X.X). | ||
|
||
IO-Link Visualization Software | ||
``````````````````````````````` | ||
A Windows software called LR Device exists for parameter setting and visualization | ||
of IO-Link master and device data. The software download link is below should the | ||
user need it for changing settings on the IO-Link master. On the LR Device software | ||
panel, click the 'read from device' button on the upper right (leftmost IOLINK | ||
button); the software will then search for the IO-Link master. Once found, it will | ||
inform the user of the IO-Link master model number (AL1340) and its IP address. | ||
|
||
- `LR Device Software <https://www.ifm.com/de/en/download/LR_Device>`_ | ||
|
||
Agent API | ||
--------- | ||
|
||
.. autoclass:: socs.agents.ifm_kq1001_levelsensor.agent.LevelSensorAgent | ||
:members: |