[HydraForce Proportional Valve](http://www.hydraforce.com/Proport/Prop_html/2-112-1_SP10-47C/2-112-1_SP10-47C.htm) * Operating Pressure: 248 bar (3600 psi)

Flow: 22.7 lpm (6 gpm) max.

Internal Leakage: 164 cc/minute (10 cu. in./minute) max. per side at 248 bar (3600 psi)

Hysteresis: Less than 7%

Temperature: -40 to 120°C with standard Buna seals

Coil Duty Rating: Standard Coils and E-Coils: Continuous up to 115% of nominal voltage

Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 7.4 to 420 cSt (50 to 2000 sus)

Cavity: VC10-4; See page 9.110.1;

Cavity Tool: CT10-4XX;